OHAUS Courier 7000 Instruction Manual page 46

Hide thumbs Also See for Courier 7000:
Table of Contents

Advertisement

EN-42
Transaction String
The length of each item in a transition string.
Reading data--6 bytes
Data polarity---1 byte: "-" for negative, and followed the first digit, " " for positive.
Decimal point--1 byte: "."
Measure unit---1-5 bytes: "Ib", "kg", "Ib:oz", "pcs", "%". Units are always lower case, left aligned.
Current status--4 bytes
If the weight is over capacity, the scale will return eight "^" characters (the field of polarity, decimal
point, weight data is filled by "^").
If the weight is under capacity, it will return eight "_" characters (the field of polarity, decimal point,
weight data is filled by "_").
If the zero point is error, it will return eight "-" characters (the field of polarity, decimal point, and
weight data is filled by "-").
Useless leading 0 before digits is suppressed. Reading weight is right aligned.
U
Bit
Byte 1 (H
)
1
0
0= stable
1= not stable
1
0= not at zero point
1= at zero point
2
0= RAM ok
1= RAM error
3
0= eeprom OK
1= eeprom error
4
always 1
5
always 1
6
always 0
7
parity
Table 6-1 Symbols Used
<LF>
Line Feed character (hex 0AH)
<CR>
Carriage Return character (hex 0DH)
<ETX>
End of Text character (hex 03H)
<SP>
Space (hex 20H)
H
H
H
H
Four current status bytes
1
2
3
4
<P>
Polarity character: "-" or " "
W
W
Reading data, 1-6 bytes (six digits)
1---
6
<DP>
Decimal point
U
U
U
U
Measure units, kg, Ib, Ib:oz, % or pcs; 2-5 bytes
1
2
3
4
5
<Add>
Address of scale; 2 bytes (00-99)
<Prompt>
Prompt characters of output content; max. 11 bytes
Table 6-2 Bit Definition of H
Byte 2 (H
)
2
0= not under capacity
1= under capacity
0= not over capacity
1= over capacity
0= ROM ok
1= ROM error
0= calibration ok
1= calibration error
always 1
always 1
always 1
parity
H
H
H
1
2
3
4
Byte 3 (H
)
3
00= compare disable
01= lower limit
10= ok
11= upper limit
0= gross weight
1= net weight
0= initial zero ok
1= initial zero error
always 1
always 1
always 1
parity
Courier 7000
Byte 4 (H
)
4
00= normal weighing
01= count weighing
10= percent weighing
11= other mode
0= not in HOLD
1= in HOLD
0= battery ok
1= low battery
always 1
always 1
always 0
parity