Download Print this page
OHAUS Ranger Count 3000 Series Instruction Manual

OHAUS Ranger Count 3000 Series Instruction Manual

Hide thumbs Also See for Ranger Count 3000 Series:

Advertisement

Quick Links

Ranger™ Count 3000 Series
Instruction Manual

Advertisement

loading

Summary of Contents for OHAUS Ranger Count 3000 Series

  • Page 1 Ranger™ Count 3000 Series Instruction Manual...
  • Page 3: Installation

    EN-1 Ranger™ Count 3000 Series 1. INTRODUCTION 1.1 Definition of Signal Warnings and Symbols Signal Words CAUTION Note Warning Symbols 1.2 Safety Precautions             2. INSTALLATION 2.1 Package Contents ...
  • Page 4 EN-2 Ranger™ Count 3000 Series 2.2 Installing Components 2.3 Selecting the Location 2.4 Leveling the Equipment...
  • Page 5 Notes lo.bat CAUTION: Battery is to be replaced only by an authorized Ohaus service dealer. Risk of explosion can occur if the rechargeable battery is replaced with the wrong type or if it is not properly connected. Dispose of the lead...
  • Page 6: Operation

    EN-4 Ranger™ Count 3000 Series 3. OPERATION 3.1 Displays Button ON/ZERO PRINT Target Units Menu Back Exit Back Exit...
  • Page 7 EN-5 Ranger™ Count 3000 Series Button Tare Sample Notes: Weight Piece Weight Item Description Item Description Notes:...
  • Page 8 EN-6 Ranger™ Count 3000 Series...
  • Page 9 EN-7 Ranger™ Count 3000 Series 3.2 Turning Scale On/Off On/Zero Off On/Zero Off 3.3 Counting 3.3.1 Preset tare Tare 3.3.2 APW Establishment Positive Sampling: Sample Sample ------ Sample ------ Negative sampling: Sample Sample ------ Sample ------...
  • Page 10 EN-8 Ranger™ Count 3000 Series Entering a known APW: ------ 3.3.3 Simple Counting Tare 3.4 Accumulation and Statistics 3.4.1 Accumulating Displayed Values 3.4.2 Viewing and Clearing Statistical Data Tare Clr.aCC Notes: When Legal for Trade is ON, the display must return to 0 gross. Otherwise, the ∑ pointer will continue flashing.
  • Page 11 EN-9 Ranger™ Count 3000 Series Tare 3.6 Check-Counting Target Target Check Count Target Under Over Tare Positive Check Negative Check Tare Zero Check Tare...
  • Page 12 EN-10 Ranger™ Count 3000 Series 3.7 Library Storing a record: Store Retrieving a record: reCall reCall Editing a record: reCall edit 000000 000000 save Clearing a record: reCall delete Printing Library record:...
  • Page 13: Menu Settings

    EN-11 Ranger™ Count 3000 Series 4. MENU SETTINGS 4.1 Menu Navigation User Menu: C.A.L S.E.t.U.P r.E.A.d U.n.i.t P.r.i.n.t.1 C.O.M.1 L.O.C.k E.n.d Notes: C.A.L...
  • Page 14 EN-12 Ranger™ Count 3000 Series Back Exit...
  • Page 15 EN-13 Ranger™ Count 3000 Series 4.2 Cal Menu Initial Calibration Procedure: Menu mMeNU C.A.L SpaN --C-- --C-- done Capacity Mass Capacity Mass Note:...
  • Page 16 EN-14 Ranger™ Count 3000 Series *Bold always represents factory default value. Zero2 [ZErO] Span1 [SpaN] Span2 [SpaN2] Lin1 [LIN] Lin2 [LIN2] GEO [GEO] End Cal [End]...
  • Page 17 EN-15 Ranger™ Count 3000 Series 4.3 Setup Menu bold auto manual Reset reset Dual Scale [d.scale] Cap2 [CAP2] Grad2 [GrAd2] Power on unit pwWr.UN Zero Range ZErO Auto Opt [A.OPt]...
  • Page 18 EN-16 Ranger™ Count 3000 Series Auto Tare A.tArE Beeper Opt [bp.OPt] Beeper Signal Bp.sIG Beeper Key BP.key Accumulation aCCUmM End Setup End...
  • Page 19 EN-17 Ranger™ Count 3000 Series 4.4 Readout Menu bold medium auto Reset reset Stable Range Stable Filter FILtEr AZT AZt Light LIGHt Auto off A.OFF End Readout End...
  • Page 20 EN-18 Ranger™ Count 3000 Series 4.5 Unit Menu Units...
  • Page 21 Ranger™ Count 3000 Series EN-19 4.6 Print1 Menu bold Note: Line Reset reset Stable Only Stable Auto Print A.Print Content CONtNt Part Number Note:...
  • Page 22 EN-20 Ranger™ Count 3000 Series Result Gross Tare Header Note: Footer Note: Mode Unit Info...
  • Page 23 Ranger™ Count 3000 Series EN-21 Accu Note: Layout layOUt Format Feed Data Transfer data.tr Notes: Print Library P.lib End Print End...
  • Page 24 EN-22 Ranger™ Count 3000 Series 4.7 COM1 Menu bold 9600 8 none none Note: Reset reset Baud Rate BAUD Parity paritY Stop bit stOP Handshake H.shake...
  • Page 25 Ranger™ Count 3000 Series EN-23 Alternate command Alt.CmM Print Tare Zero End COM1, End COM2 End 4.8 Lock Menu bold Reset reset Lock Cal l.CAL Lock Setup L.SetuP Lock Read L.read Lock Unit l.Unit...
  • Page 26 EN-24 Ranger™ Count 3000 Series Lock Print l.print Lock COM l.COmM End Lock End 4.9 End Menu 4.10 Additional Features Note:...
  • Page 27 Ranger™ Count 3000 Series EN-25 Elevation in meters 1300 1625 1950 2275 2600 2925 3250 1300 1625 1950 2275 2600 2925 3250 3575 Elevation in feet 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 1060 2130 3200 4260 5330 6400 7460...
  • Page 28: Legal For Trade

    EN-26 Ranger™ Count 3000 Series 5. LEGAL FOR TRADE 5.1 Capacity Label Note: 5.2 Settings Note: C.A.L 5.3 Verification and Sealing 5.3.1 Physical Seals...
  • Page 29 Ranger™ Count 3000 Series EN-27 5.3.2 Audit Trail Seal (USA and Canada only) Note:  ...
  • Page 30: Maintenance

    EN-28 Ranger™ Count 3000 Series 6. MAINTENANCE 6.1 Cleaning 6.2 Troubleshooting Symptom Possible Cause Remedy Err 8.1 Err 8.2 Err 8.3 Err 8.4 Err 8.5 Err 8.6 Err 9.5 ------- --NO-- CAL E Lo.REF rEF.Err NO.ACC...
  • Page 31 EN-29 Ranger™ Count 3000 Series 6.3 Service Information www.ohaus.com 6.4 Accessories...
  • Page 32: Technical Data

    EN-30 Ranger™ Count 3000 Series 7. TECHNICAL DATA 7.1 Specifications MODEL RC31P1502 RC31P3 RC31P6 RC31P15 RC31P30          ...
  • Page 33 Ranger™ Count 3000 Series EN-31 7.2 Drawings...
  • Page 34 EN-32 Ranger™ Count 3000 Series 7.3 Communication 7.3.1 Interface Commands Command Function 7.3.2 Connections for RS232...
  • Page 35 EN-33 Ranger™ Count 3000 Series 7.4 Printouts Print Description Comment PN: 123456789926   PCS N   0.1420 kg G   0.0420 kg N   0.1000 kg PT   APW: 0.11500 g   N: 3 ...
  • Page 36 EN-34 Ranger™ Count 3000 Series 7.6 Compliance Mark Standard Important notice for verified weighing instruments...
  • Page 37 EN-35 Ranger™ Count 3000 Series Disposal FCC Note Industry Canada Note ISO 9001 Registration...
  • Page 38 EN-36 Ranger™ Count 3000 Series Limited Warranty...
  • Page 39 Dirección. Calle UVA 6121 Cd. Juárez, Chih. Tel. • (656) 233 0828 • (656) 208-3474 • (656) 655 8604 www.mastersupply.com.mx...
  • Page 40 *30037454*...