Function
Name
Code
Running Status
Display
b06.00
Selection
Stop Status
Display
b06.01
Selection
Keypad
Display
b06.02
Selection
Relay Output
b06.03
Selection
Factory
Setting Range
Setting
0~0x1FF
0x01F
0~0x1FF
0x001F
0~3
0~5
4 15
bit0: Operational frequency
bit1: The actual pressure of pump
outlet
bit2: The setting pressure of pump
outlet
bit3: Output current
bit4: DC bus voltage
bit5: Output voltage
bit6: Present time
bit7: The actual pressure of pump
inlet
bit8: Input terminal status
bit0: The setting pressure of pump
outlet
bit1: The actual pressure of pump
outlet
bit2: Giver frequency
bit3: DC bus voltage
bit4: Input terminal status
bit5: Output terminal status
bit6: Al1 input voltage
bit7: The actual pressure of pump
inlet
Bit8: Present time
0: External keypad prior enable
1: Both display enable, only external
keypad control
2: Both display enable, only on board
3
keypad control
3: Both display enable and keypad
control.
0: Error or external fault
1: Forward running
2: Frequency reaching
3: Stop status
0
4: Lower limit of output frequency
reaching
5: The frequency is not equal to zero
Description