DAYLIFF PVm015 Installation & Operating Manual page 15

Pumpverter vfd controller

Advertisement

Function
Name
Code
b03.08
Slave Quantity
Fault Shift/
b03.09
Standby Master
Sleeping
b04.00
Function
Sleeping
b04.01
Waiting Time
Sleeping
b04.02
Test
Wake up
b04.03
Pressure Bias
Sleeping
b04.04
Bias
Water Level
b05.00
Control
Low Level
Restart Delay
b05.01
Time
Terminal S1S2
Control
b05.02
Factory
Setting Range
Setting
0~5
0~2
0~1
0.0~300.0s
5.0s
0.0~10.0%
4.0%
0.0~20.0bar 0.5bar
0.0~1.0bar 0.0bar
0~2
0~300min
1min
0~3
4 13
0
0: None
Fault Master Shift
Invalid: Factory Setting: 2
Valid: Master set as 0;
Slave1 set as 1
2
Re m a r k s : Fa u l t s h i f t r e q u i r e s
connection of backup transducer to
Slave 1. Slave 1 acts as standby
master.
No consuming auto stop
1
0:Invalid
Delay time
Water consuming test frequency rate
During sleep the wake-up pressure
bias e.g. the setting value (L)=3.0bar,
bias (b04.03)=0.5bar, practical
pressure (P)<L-0.5=2.5bar, the
pump will restart again.
The pressure fluctuation which allows
sleeping
Water level switch style
2
0: Invalid 1: NC 2: NO
Delay time of restart after water level
recover
0: Invalid
1: Electric Contact Control
2
S1-COM on: Frequency rise
S2-COM on: Frequency drop
2. Manual/Auto Control
S2-COM off: Auto Control
S2-COM on: Manual Control
3. Terminal run/stop
S1-COM on: Run
S1-COM off: Stop
S2-COM off: Auto Control
S2-COM on: Manual Control
Description
1: Valid