Technical data
Saturn 256 DG
8
Technical data
Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1
Saturn 256 DG
Switching steps
Welding current setting range
Duty cycle at 25°C ambient temperature
30 %
100 %
Open circuit voltage
Mains connection lead
Mains voltage (tolerances)
Frequency
Mains fuse (slow-blow safety fuse)
Max. connected power
Recommended generator power
Workpiece lead
Cosϕ
Insulation class/protection classification
Ambient temperature
Machine cooling / torch cooling
Dimensions (L x W x H in mm)
Weight
Constructed to standards
28
NOTE
30 A - 250 A
250 A
140 A
17,8 V to 38,3 V
3 x 2,5 mm²
230 V (+/- 15%)
50/60 Hz
25 A
9,7 kVA
13,1 kVA
50 mm²
0.98
H/IP 23
-20°C to +40°C
Fan / gas
950 x 410 x 860
93 kg
IEC 60974-1, -10
12
/
099-005167-EW501
29.06.2010