Technical Data; Technical Data Multi-Turn Actuators - AUMA SAV 07.2 Operation Instructions Manual

Multi-turn actuators control unit: electronic (mwg) with actuator controls acv 01.2 non-intrusive multiport valve version
Hide thumbs Also See for SAV 07.2:
Table of Contents

Advertisement

SAV 07.2
SAV 16.2/SARV 07.2
ACV 01.2 Modbus TCP/IP
13.

Technical data

Information
13.1.

Technical data Multi-turn actuators

Features and functions
Type of duty
(Multi-turn actuators for open-close
duty)
Type of duty
(Multi-turn actuators for modulating
duty)
Motors
Mains voltage, mains frequency
Overvoltage category
Insulation class
Motor protection
Self-locking
Motor heater (option)
Manual operation
Indication for manual operation (op-
tion)
Electrical connection
Threads for cable entries
Terminal plan
Valve attachment
SARV 16.2 Control unit: electronic (MWG)
The following tables include standard and optional features. For detailed information
on the customer-specific version, refer to the order-related data sheet. The technical
data sheet can be downloaded from the Internet in both German and English at ht-
tp://www.auma.com (please state the order number).
Standard:
Short-time duty S2 - 15 min, classes A and B according to EN 15714-2
Option:
Short-time duty S2 - 30 min, classes A and B according to EN 15714-2
For 100 % nominal voltage and +40 °C ambient temperature and at run torque load at maximum output
speed.
Standard:
Intermittent duty S4 - 25 %, class C according to EN 15714-2
Option:
Intermittent duty S4 - 50 %, class C according to EN 15714-2
For 100 % nominal voltage and +40 °C ambient temperature and at modulating torque load.
3-phase AC asynchronous motor, type IM B9 according to IEC 60034-7, IC410 cooling procedure ac-
cording to IEC 60034-6
Refer to name plate of ACV actuator controls
Permissible variation of mains voltage: ±10 %
Permissible variation of mains frequency: ±5 %
Category III according to IEC 60364-4-443
Standard:
F, tropicalized
Option:
H, tropicalized
Thermoswitches (NC)
Self-locking: Speed ranges 6
NOT self-locking: Speed range variant 24
Applications of NON self-locking speed variants with pulling loads (like protective weirs, fishbelly flap
gates and sluice gates, etc.) on request.
Multi-turn actuators are self-locking if the valve position cannot be changed from standstill while torque
acts upon the output drive.
Voltages:
110
120 V AC, 220
Power depending on the size 12.5
Manual drive for setting and emergency operation, handwheel does not rotate during electrical operation.
Option:
Handwheel lockable
Handwheel stem extension
Power tool for emergency operation with square 30 mm or 50 mm
Indication whether manual operation is active/not active via single switch (1 change-over contact)
Standard:
AUMA plug/socket connector with screw-type connection
Option:
Terminals or crimp connection
Gold-plated control plug (sockets and plugs)
Standard:
Metric threads
Option:
Pg-threads, NPT-threads, G-threads
Terminal plan according to order number enclosed with delivery
Standard:
B1 according to EN ISO 5210
Option:
A, B2, B3, B4 according to EN ISO 5210
A, B, D, E according to DIN 3210
C according to DIN 3338
Special valve attachments: AF, AK, AG, B3D, ED, DD, IB1, IB3
A prepared for permanent lubrication of stem
60 rpm and 12
120 rpm
240 rpm
240 V AC or 380
480 V AC
25 W
Technical data
73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sav 16.2Sarv 07.2Sarv 16.2