7
DIGITAL SELECTIVE CALLING (DSC)
■ DSC Remote Control
With controllers connected to the transceiver, you can perform DSC remote control
communications. Up to 3 command microphones and an external device can be used as
controllers.
For more information about connecting an external device, see page 82.
D Editing a controller name
A name can be assigned to each controller for easy identification.
1.
Open the "NAME" screen.
[MENU] > Settings > Configuration > Controller > Name
L Only controllers connected to the transceiver
are listed.
L The controller being operated has "(Own)"
appended to its name.
2.
Push [▲] or [▼], or rotate [DIAL] to select a
controller.
3.
Push [ENT] or [DIAL] to enter the
screen.
4.
Edit a controller name.
L Select
5.
Select
the previous screen.
D Setting the Priority Controller
Select which controller to be used as the Priority Controller.
The Priority Controller takes precedence over other controllers in DSC operations.
Except for sending a Distress call, a DSC task can be handled only by the first controller
operated.
1.
Open the "PRIORITY" screen.
[MENU] > Settings > Configuration > Controller > Priority
L Only controllers connected to the transceiver
are listed.
L The controller being operated has "(Own)"
appended to its name.
2.
Push [▲] or [▼], or rotate [DIAL] to select a
controller to be used as the Priority Controller.
L The Priority Controller's ID is automatically
set to 0.
NOTE:
• If the ID of the external device is set to 0, the device is automatically set as the
Priority Controller.
• When the external device is set as the Priority Controller, regardless of its ID,
DSC remote control from the device is accepted.
49
"NAME"
to enter numbers, and
, and then push [ENT] or [DIAL] to save the edited name and return to
(EN 300 338-8 compatible)
to enter symbols.
Need help?
Do you have a question about the IC-M510BB and is the answer not in the manual?
Questions and answers