USER MANUAL
A6000
AC POWER SOURCE
6.10 Command for Remote Control
6.10.1 IEEE 488.2 Standard Command
*ESE <n> Set flag mask of standard event status register.
bit
Bit name
Bit
definition
*ESE?
*ESR?
*IDN?
*RST
*RCL <n> Recall stored system setting.
*SAV <n> save system setting
*SRE <n> Flag mask setting for service events status register
Bit
name
definition
*SRE?
*STB?
*CLS
1. Leave out REMOTE control, back to panel control.
2. When one of the following error occurs, turn off output, clear error status, back to main
manual
Software OCP
D2A OCP Fault
D2A OPP Fault
78
│ www.deltaww.com
This command is for a register used for IEE488.2 defined standard events. It is
used for flag mask or control enable. Set by 1 enables target event detection,
and event detection is masked if setting is 0. No response to target events
when 0 is set. Bits configuration for standard events register are:
7
6
5
PON
----
CME
Power
Command
on
error
Query flag mask for standard event status register.
Query value stored in standard events status register, 1 represents event
occurs.
Return string of AC source identification.
Parameter returns
DME-A602ABS A
000,000
Make all parameters setting back to default factory setting. Must wait 10
seconds before sending next command.
Parameter: 1~4
Parameter: 1~4
This command is for a register used for IEE488.2 and instrument defined
service events. It is used for flag mask or control enable. Set by 1 enables
target event detection, and event detection is masked if setting is 0. No
response to target events when 0 is set. Bits configuration for service events
register:
7
6
----
MSS/SRQ
Service
request
Return status of flag mask status for service events.
Query value stored in service event register, 1 represents event occurs.
Clear status. Following operation may execute depends on different conditions.
4
EXE
Execution
Error related
error
to instrument
: DME-A602ABS A,000,000
: Name of AC source
: Version of firmware
5
ESB
Brief info. For service
event register
3
2
DDE
QYE
----
Query
error
4
3
MAV
----
Info.
available
1
0
OPC
Operation
completed
2
1
0
----
----
----