[SOURce:]STEP:SPHase
Function
Example
Parameter : <NR2> , effective range: 0~359
Parameter returns: <NR2>
[SOURce:]STEP:DWELl
Function
Example
Parameter : <NR2> , effective range: 1~16000000 (unit: ms)
Parameter returns: <NR2>
[SOURce:]STEP:COUNt
Function
Example
Parameter : <NR1> , effective range: 0~10000
Parameter returns: <NR1>
[SOURce:]SYNThesis
Function
Example
Parameter : DST30 | DST31
[SOURce:]SYNThesis:AMPLitude
Function
Example
Parameter : <NR2>,...,<NR2>
Effective range:
Parameter returns: <NR2>,...,<NR2>
93
│ www.deltaww.com
: Set(query) start phase angle at STEP mode.
: [SOURce:]STEP:SPHase?
[SOURce:]STEP:SPHase 80
: Set (query) output duration for each step in STEP mode.
: [SOURce:]STEP:DWELl?
[SOURce:]STEP:DWELl 1000
: Set (query) how many steps to execute STEP mode.
: [SOURce:]STEP:COUNt?
[SOURce:]STEP:COUNt 500
: Set (query) which synthesis waveform to use. There are DST30 and DST31
available.
: [SOURce:]SYNThesis ?
[SOURce:]SYNThesis DST30
: Set (query) voltage amplitude for each order of harmonic waveforms.
Maximum order is 39.
: [SOURce:]SYNThesis:AMPLitude?
[SOURce:]SYNThesis:AMPLitude 20.55 33.10 2.55
Order
N=2~N=20
N=21~N=30
N=31~N=39
Gain limit
33.33%
30.00%
15.00%