USER MANUAL
A6000
AC POWER SOURCE
Instrument command
FETCh | MEASure
:CURRent
:AC?
:1?
:2?
:AMPLitude:MAXimum?
:1?
:2?
:CREStfactor?
:1?
:2?
:INRush?
:1?
:2?
:FREQuency?
:1?
:2?
:POWer
:AC?
[:REAL]?
:APParent?
:REACtive?
:PFACtor?
:VOLTage
:AC?
:1?
:2?
OUTPut
:MODE
[SOURce:]
CURRent
:LIMit
:DELay
96
│ www.deltaww.com
:1?
:2?
:1?
:2?
:1?
:2?
:1?
:2?
Query the total AC rms current
Query the phase 1 AC rms current
Query the phase 2 AC rms current
Query the total peak current
Query the Phase 1 peak current
Query the Phase 2 peak current
Query the total current crest factor
Query the phase 1 current crest factor
Query the phase 2 current crest factor
Query the total inrush current
Query the phase 1 inrush current
Query the phase 2 inrush current
Query average frequency
Query phase 1 frequency
Query phase 2 frequency
Query total real power
Query phase 1 real power
Query phase 2 real power
Query total apparent power
Query phase 1 apparent power
Query phase 2 apparent power
Query total reactive power
Query phase 1 reactive power
Query phase 2 reactive power
Query average power factor
Query phase 1 power factor
Query phase 2 power factor
Query average AC Vrms
Query phase 1 AC Vrms
Query phase 2 AC Vrms
set or query output status
set or query output mode
Set (query) total output current limitation Irms
Set (query) delay time to trigger over current protection