USER MANUAL
A6000
AC POWER SOURCE
It takes about 8 seconds to do the calculation and saving. It will back to first page of
SYNTHESIS when saving is completed. For protection purpose, amplitude for each order
must not exceed limitation as below.
Example of SYNTHESIS mode:
Order
2
5
7
8
Output waveform
+2.07
= 110 ×
+9.80
+15.80
+2.16
71
│ www.deltaww.com
Gain
Phase
2.07
0.0
9.80
0.0
15.80
0.0
2.16
0.0
× sin(2ωt+0.0)
sin(ωt)
× sin(5ωt+0.0)
× sin(7ωt+0.0)
× sin(8ωt+0.0)
Orders
Gain limit
2 ~ 20
21 ~ 30
31 ~ 39
33.33%
30.00%
15.00%