Delta A6000 User Manual page 94

Table of Contents

Advertisement

USER MANUAL
A6000
AC POWER SOURCE
[SOURce:]PULSe:VOLTage:AC
Function
Example
Parameter : <NR2> , effective range: 0.0~150.0 (low voltage range),
Parameter returns: <NR2>
[SOURce:]PULSe:FREQuency
Function
Example
Parameter : <NR2> , effective range: 30.0~1000.0 (unit: Hz)
Parameter returns: <NR2>
[SOURce:]PULSe:SPHase
Function
Example
Parameter : <NR2> , effective range: 0~359
Parameter returns: <NR2>
[SOURce:]PULSe:COUNt
Function
Example
Parameter : <NR1> , effective range: 0~10000
Parameter returns: <NR1>
[SOURce:]PULSe:DCYCle
Function
Example
Parameter : <NR1> , effective range: 1~15999999 (unit: msec)
Parameter returns: <NR1>
91
│ www.deltaww.com
: Set (query) AC voltage of PULSE output.
: [SOURce:]PULSE:VOLTage:AC?
[SOURce:]PULSE:VOLTage:AC 250.1
: Set (query) frequency of PULSE waveform.
: [SOURce:]PULSE:FREQuency?
[SOURce:]PULSE:FREQuency 50.0
: Set (query) start phase angle of PULSE waveform.
: [SOURce:]PULSE:SPHase?
[SOURce:]PULSE:SPHase 60
: Set (query) how many times to execute PULSE voltage.
: [SOURce:]PULSE:COUNt?
[SOURce:]PULSE:COUNt 500
: Set (query) execution time of PULSE waveform, it must be no longer than
total period in PULSE mode.
: [SOURce:]PULSE:DCYCle?
[SOURce:]PULSE:DCYCle 300