Delta A6000 User Manual page 92

Table of Contents

Advertisement

USER MANUAL
A6000
AC POWER SOURCE
[SOURce:]PHASe:ON
Function
Example
Parameter : <NR2> , effective range: 0~359
Parameter returns: <NR2>
[SOURce:]PHASe:OFF
Function
Example
Parameter : <NR2> , effective range: 0~360 , 360 representing turn off immediately
Parameter returns: <NR2>
[SOURce:]PHASe:2
Function
Example
Parameter : <NR2> , effective range: 0.0~359.9 , default is 180 .
Parameter returns: <NR2>
[SOURce:]LIST:COUNt
Function
Example
Parameter : <NR1> , effective range: 0~10000
Parameter returns: <NR1>
[SOURce:]LIST:DWELl
Function
Example
Parameter : <NR2>,...,<NR2> , effective range: 0~16000000 (unit: msec)
Parameter returns: <NR2>,...,<NR2>
[SOURce:]LIST:SHAPe
Function
Example
Parameter : A|B,...,A|B
Parameter returns: A|B,...,A|B
89
│ www.deltaww.com
: Set (query) waveform start phase angle set at main manual.
: [SOURce:]PHASe:ON?
[SOURce:]PHASe:ON 200
: Set (query) waveform stop phase angle set at main manual.
: [SOURce:]PHASe:OFF?
[SOURce:]PHASe:OFF 250
: Set (query) phase angle of phase 1 leads phase 2.
: [SOURce:]PHASe:2?
[SOURce:]PHASe:2 200
: Set (query) how many times to execute effective sequences in LIST mode.
: [SOURce:]LIST:COUNt?
[SOURce:]LIST:COUNt 100
: Set (query) execution time for 10 individual sequences in SERIES mode.
: [SOURce:]LIST:DWELl?
[SOURce:]LIST:DWELl 16000000 1 23 95
: Set (query) waveform buffer used for 10 individual sequences in SERIES
mode.
: [SOURce:]LIST:SHAPe?
[SOURce:]LIST:SHAPe A B A A A

Advertisement