USER MANUAL
A6000
AC POWER SOURCE
 TRIG: TTL signal changes from HIGH→LOW, and keeps low longer than 1ms, DME-
A602ABS SERIES turn off output, and stop detecting TTL signal, output stay at off state
even TTL signal changes to high. User must press
TTL signal detecting.
 EXCITE: When user is using LIST, PULSE and STEP modes, at trigger page (please
refer 4.2~4.4), by positive edge trigger TTL signal (LOW→HIGH) can trigger DME-
A602ABS SERIES output ON/OFF, pulse signal must keep at least 1ms when signal
changes.
 When AC source output is at turn off status, TTL signal changes from LOW→HIGH
will enable trigger signal and turn on output, there are two conditions may happen:
 If output sequences finished and TTL signal changes from LOW→HIGH again, will
output trigger signal again and turn on output repeat the sequences.
 If TTL signal changes from LOW→HIGH when output sequences are not finished
yet, output will turn off.
Example how to change Remote Inhibit setting from OFF to TRIG:
1. Press
51
│ www.deltaww.com
or
to move cursor to Remote Inhibit