Delta A6000 User Manual page 93

Table of Contents

Advertisement

USER MANUAL
A6000
AC POWER SOURCE
[SOURce:]LIST:VOLTage:AC:STARt
Function
Example
Parameter : <NR2>,...,<NR2> , effective range: 0.0~150.0 (low voltage range),
Parameter returns: <NR1>,...,<NR2>
[SOURce:]LIST:VOLTage:AC:END
Function
Example
Parameter : <NR2>,...,<NR2> , effective range: 0.0~150.0 (low voltage range),
Parameter returns: <NR2>,...,<NR2>
[SOURce:]LIST:FREQuency:STARt
Function
Example
Parameter : effective range: 30.0~1000.0 (unit: Hz)
Parameter returns: <NR2>,...,<NR2>
[SOURce:]LIST:FREQuency:END
Function
Example
Parameter : <NR2>,...,<NR2> , effective range: 30.0~1000.0 (unit: Hz)
Parameter returns: <NR2>,...,<NR2>
[SOURce:]LIST:DEGRee
Function
Example
Parameter : <NR2>,...,<NR2> , effective range: 0~359
Parameter returns: <NR2>,...,<NR2>
90
│ www.deltaww.com
: Set (query) start voltage for 10 individual sequences in SERIES mode.
: [SOURce:]LIST:VOLTage:AC:STARt?
[SOURce:]LIST:VOLTage:AC:STARt 110 22.5 55.6
: Set (query) stop voltage for 10 individual sequences in SERIES mode.
: [SOURce:]LIST:VOLTage:AC:END?
[SOURce:]LIST:VOLTage:AC:END 1.2 50 66.6
: Set (query) start frequency for 10 individual sequences in SERIES mode.
: [SOURce:]LIST:FREQuency:STARt?
[SOURce:]LIST:FREQuency:STARt 50.8 80.5 952.2
: Set (query) start frequency for 10 individual sequences in SERIES mode.
: [SOURce:]LIST:FREQuency:END?
[SOURce:]LIST:FREQuency:END 220.5 30.8 77.8
: Set (query) start phase angle for 10 individual sequences in SERIES mode.
: [SOURce:]LIST:DEGRee?
[SOURce:]LIST:DEGRee 30 96 88 71
0.0~300.0 (high voltage range)
0.0~300.0 (high voltage range)