Delta A6000 User Manual page 58

Table of Contents

Advertisement

USER MANUAL
A6000
AC POWER SOURCE
 Protections by hardware:
Errors
AUX PG Fault
D2A IC Fault
D2A OCP Fault
D2A OPP Fault
D2A OTP Fault
D2D OTP Fault
D2D PG Fault
FAN Fault
Input OCP
PFC AC Fault
PFC OVP Fault
PFC OTP Fault
PFC PG Fault
Notes:
55
│ www.deltaww.com
Status description
AUX Power output abnormal
Voltage / current detection IC malfunction
Over current
Over power for D2A Board
Over temperature for D2A Board
Over temperature for D2D Board
Output abnormal for D2D Board
Fan malfunction
Input current reaches trip point of built in no fuse breaker
AC mains voltage higher or lower than rating ranges
Over voltage for PFC Board
Over temperature for PFC Board
Output abnormal for PFC Board
1. DME-A602ABS SERIES has one no fuse breaker at AC input side, its
current rating is 20A. AC source will enter protection status when AC
input current is over 20A.
2. D2A OCP ranges: When Voltage Level is 300V, OCP trigger point is
32A. It is 64A when voltage Level is set at 150V.
2
for D2D Board
1

Advertisement

Table of Contents
loading

Table of Contents