Command For Remote Control; Ieee 488.2 Standard Command - Delta A1500 Series User Manual

Table of Contents

Advertisement

User Manual
A1500
AC Power Source

4.3 Command for Remote Control

4.3.1 IEEE 488.2 Standard Command

*ESE <n>
bit
Bit name
Bit
definition
*ESE?
*ESR?
*IDN?
*RCL <n>
*SAV <n>
*SRE <n>
Bit
name
definition
59
│ www.deltaww.com
Set flag mask of standard event status register.
This command is for a register used for IEEE488.2 defined standard events. It
is used for flag mask or control enable. Set by 1 enables target event detection,
and event detection is masked if setting is 0. No response to target events
when 0 is set. Bits configuration for standard events register are:
7
6
5
PON
----
CME
Power
Command
on
error
Query flag mask for standard event status register.
Query value stored in standard events status register, 1 represents event
occurs.
Return string of AC source identification.
Parameter returns : DME-ACS1152B X,000,000
 DME-ACS1152B X
 000,000
Recall stored system setting.
parameter:1~3
Save system setting
parameter:1~3
Flag mask setting for service events status register
This command is for a register used for IEE488.2 and instrument defined
service events. It is used for flag mask or control enable. Set by 1 enables
target event detection, and event detection is masked if setting is 0. No
response to target events when 0 is set. Bits configuration for service events
register:
7
6
----
MSS/SRQ
Service
request
4
3
EXE
DDE
Execution
Error related
error
to instrument
: Name of AC source
: Version of firmware
5
ESB
Brief info. For service
event register
2
1
QYE
----
Query
error
4
3
MAV
----
Info. available
0
OPC
Operation
completed
2
1
0
----
----
----

Advertisement

Table of Contents
loading

This manual is also suitable for: