A6000
AC Power Source
User Manual
www.deltaww.com

Advertisement

Table of Contents
loading

Summary of Contents for Delta A6000

  • Page 1 A6000 AC Power Source User Manual www.deltaww.com...
  • Page 2: Table Of Contents

    USER MANUAL A6000 AC POWER SOURCE Warranty ............................1 Warranty Coverage ...........................1 Safety Summary ..........................2 Safety Symbols..........................3 Accessories ............................4 Revision History..........................5 1. General Information ........................6 1.1 Introduction ...........................6 1.2 Key Features .........................6 1.3 Specifications ........................6 1.4 Name of Parts ........................8 1.4.1 The Front Panel ......................8 1.4.2 The Rear Panel......................10...
  • Page 3 USER MANUAL A6000 AC POWER SOURCE 3.14 Waveform Selection ......................37 3.15 Buzzer ..........................39 3.16 Disable (Lock) the Keys at Front Panel ................40 3.16.1 Set Series / Parallel Output Mode ................41 3.17 CONFIG Function .......................42 3.18 Waveform A, B Generator ....................43 3.19 GPIB, RS232 Communication Setting ................47...
  • Page 4: Warranty

    Delta electronics branches to get service. Warranty Coverage Within warranty limited and product need to replace components. Delta may claim charge or refuse to repair under following conditions: Products repaired or altered by persons not authorized by Delta, or not in accordance with instructions provided by Delta.
  • Page 5: Safety Summary

    Delta assumes no liability for the customer‘s failure to comply with these requirements. BEFORE APPLYING POWER Verify that the product is set to match with the line voltage.
  • Page 6: Safety Symbols

    USER MANUAL A6000 AC POWER SOURCE Safety Symbols DANGER - High voltage. Output of AC power source can provide peak voltage up to 426V, touched by personnel may lead to death Attention: To avoid injury, death of personnel, or damage to the instrument, the operator must refer to an explanation in the instruction manual.
  • Page 7: Accessories

    AC POWER SOURCE Accessories Please check the following accessories are included and not damaged during shipment. If there are damaged or shortage of the accessories, please contact Delta Electronics or sales agent for help. P/N: XXXXXXXXXX QTY: X P/N: XXXXXXXXXX...
  • Page 8: Revision History

    USER MANUAL A6000 AC POWER SOURCE Revision History The following list indicates the additions, deletions and modifications in this manual at each revision. Version Date Revised section June 20 , 2018 Issue │ www.deltaww.com...
  • Page 9: General Information

    The operation specifications of DME-A602ABS SERIES Programmable AC Power Source are listed below. All specifications have been tested according to the standard of Delta test procedures. All specifications are based on resistor load with remote sense connection, under 25±1ºC unless specified otherwise.
  • Page 10 USER MANUAL A6000 AC POWER SOURCE Resolution 0.1 V Distortion 1% (30Hz~1kHz) Line Regulation 0.1% Load Regulation 0.2% Temp. coefficient 0.02% per degree from 25°C Current Accuracy (rms) 0.4%+0.3%F.S. Accuracy (peak) 0.4%+0.6%F.S. Resolution 0.01 A Max. current / phase 60A / 30A / 15A (150V/300V/600V)
  • Page 11: Name Of Parts

    USER MANUAL A6000 AC POWER SOURCE 1.4 Name of Parts 1.4.1 The Front Panel │ www.deltaww.com...
  • Page 12 USER MANUAL A6000 AC POWER SOURCE Front Panel Description Item Symbol Description LCD panel, display setting and measurement results. LED indicator: • OUT (green) indicate AC source normal output • TRIGGER (yellow) indicate LIST, PULSE, STEP output Short press: Cursor move upward or downward.
  • Page 13: The Rear Panel

    USER MANUAL A6000 AC POWER SOURCE 1.4.2 The Rear Panel Rear Panel Description Item Name Description The 9-pin, D-type female connector conveys TTL signals TTL I/O (AC_ON, FAULT_OUT and REMOTE_INHIBIT). GPIB connector IEEE 488 standard connector, for remote control. RS-232 D type 9Pin female connector, for remote control.
  • Page 14: Installation

    If any damage is found, please file a claim against the carrier immediately. Do not return the instrument to the factory without obtaining the prior RMA acceptance from Delta. 2.2 Preparation for the Use Before start using, the instrument must be connected with an appropriate AC line input.
  • Page 15 USER MANUAL A6000 AC POWER SOURCE See Figure 2.3.2.1~2.3.2.4 and do the following steps one by one: 1. Remove the safety cover at the back side of AC source. 2. Connect the AC input cables to the terminal blocks of the AC source as Figure 2.3.2.1/ 2.3.2.3 shows.
  • Page 16: Output Connection

    USER MANUAL A6000 AC POWER SOURCE Figure 2.3.2.3 380Vac 3 phase 5 wires Y Input Connection (for DME-A602ABS B) Figure 2.3.2.4 380V Input terminal 2.4 Output Connection 2.4.1 Output connection Output connection is different for series or parallel operation, choose the correct one before connecting.
  • Page 17: Remote Sense Connection

    USER MANUAL A6000 AC POWER SOURCE 2.5 Remote Sense Connection The AC source remote sense function monitors the load terminal voltage instead of the AC source output terminal. It ensures the delivery of accurate voltage as programmed at the load by compensating the output voltage drop over the connecting cable automatically.
  • Page 18 USER MANUAL A6000 AC POWER SOURCE Figure 2.5.2 parallel Output and remote sense connection *** CAUTION *** Before turning on the instrument, all protective earth terminals, extension cords, and devices connected to the instrument must be connected to a WARNING protective ground.
  • Page 19: The Procedures To Power-On

    USER MANUAL A6000 AC POWER SOURCE 2.6 The Procedures to Power-on Connect the AC voltage, and turn on the power switch on the front panel. The AC source will do a series of self-tests every time it is turned on. The LCD on the front panel...
  • Page 20: Local Operation

    USER MANUAL A6000 AC POWER SOURCE 3. Local Operation 3.1 Introduction The AC source can be configured to operate in local or remote mode. The operation in remote mode through GPIB controller or RS-232C will be described in Chapter 6. This chapter describes the operation in local mode through the keypad on the front panel for data entry and test.
  • Page 21: Operation Through Keypad And Knob

    USER MANUAL A6000 AC POWER SOURCE 3.2 Operation through Keypad and Knob DME-A602ABS series provides a user-friendly programming interface by using the keypad on the front panel. Press move cursor between voltage and frequency to make selection. Use numerical and decimal point key or knob to set number, press to confirm selection.
  • Page 22 USER MANUAL A6000 AC POWER SOURCE The command tree is shown as below: │ www.deltaww.com...
  • Page 23: Main Manual Setting

    USER MANUAL A6000 AC POWER SOURCE 3.3 Main Manual Setting After the AC source is on and initialization is finished, screen will show the main manual. Default output voltage and frequency is 110V and 60Hz. Voltage and frequency setting shown on upper place on the screen, lower place of the screen shows the measurement value, example shown as below.
  • Page 24 USER MANUAL A6000 AC POWER SOURCE Example below shows how to set V=220V and F=50Hz 1. Press to move cursor to V command position (default setting) 2. Change parameter to 220 by using numerical key or rotating knob, then press confirm.
  • Page 25 USER MANUAL A6000 AC POWER SOURCE 3. Press to move cursor to F position. 4. Change parameter to 50 by using numerical key or rotating knob, press confirm │ www.deltaww.com...
  • Page 26: Series/Parallel Output Setting

    USER MANUAL A6000 AC POWER SOURCE 3.5 Series/parallel Output Setting At main manual, press to change editing (setting) or output mode. At output mode, AC source outputs according the voltage and frequency set at main manual. Measurement values are shown at the lower position of the screen. Following explains the meaning of measurement information at different output mode (series or parallel operation) 1.
  • Page 27: Output In Series Mode

    USER MANUAL A6000 AC POWER SOURCE  PF : Power Factor measurement value. Calculation equation is Real power/ (Vrms x Irms).  CF : Crest Factor, calculation equation is Ipeak/Irms.  VA : Apparent power, calculation equation is Vrms x Irms.
  • Page 28: Advanced Parameter Setting Manual

    USER MANUAL A6000 AC POWER SOURCE Measurement items below "Meter Report" will keep unchanged until operator switch to other page. For example: At "OUT MODE", switch Meter Report to Φ1. Stop the output and start again after set new parameter. During the process mentioned above, measurement items below "Meter Report"...
  • Page 29: Setup Manual

    USER MANUAL A6000 AC POWER SOURCE User can choose item 1~6, then press enter detail setting manual; Or press back to main manual. When screen is not at main manual, press will back to main manual no matter which page it is at. Press will back to advanced parameter setting manual.
  • Page 30 USER MANUAL A6000 AC POWER SOURCE 3. Press back to previous page Definitions for all parameters are listed as below: Setting Range Parameter Definition Unit V Limit Maximum voltage setting for all pages 150.0 / 300.0 I Limit Maximum output Irms 64.0 / 32.0...
  • Page 31: Voltage Limit

    USER MANUAL A6000 AC POWER SOURCE 3.8 Voltage Limit To limit the maximum output voltage for all pages, it is related to Voltage Level parameter, resolution is 0.1V: Voltage Level V Limit 300V 0.0~300.0 V 150V 0.0~150.0 V It is Firmware to set the limitation instead of by Hardware.
  • Page 32: I Limit, Ocp Delay

    USER MANUAL A6000 AC POWER SOURCE 3.9 I Limit, OCP Delay I Limit represents Current Limit, it is used to set the maximum sum current (rms) for two phase. Its range is related to Voltage Level setting: Voltage Level I Limit 300V 0.0~32.0 A...
  • Page 33 USER MANUAL A6000 AC POWER SOURCE 2. Change to 3A by numerical key or knob, then press key to confirm the setting 3. Press to move cursor to OCP Delay │ www.deltaww.com...
  • Page 34: Voltage Level Setting

    USER MANUAL A6000 AC POWER SOURCE 4. Change to 1.5s by numerical key or knob, then press key to confirm the setting 3.10 Voltage Level Setting DME-A602ABS SERIES provide two output voltage levels used for low voltage and high voltage applications. At 300V level, AC source can provide 32A in total; At 150V level 64.0A in total can be provided, maximum output power is 6000W.
  • Page 35: Voltage Sense

    USER MANUAL A6000 AC POWER SOURCE 2. Rotate knob to change <300V> to <150V>, then press to confirm setting 3.11 Voltage Sense Voltage Sense determine output voltage measurement point is at AC output terminal (Vout) or input terminal at product under testing (Vsense). If it is set at Vsense, Remote Sense wire must be connected first, otherwise compensate error will occur.
  • Page 36: Degree On, Off

    USER MANUAL A6000 AC POWER SOURCE 2. By rotating knob to change parameter to Vsense, then press to confirm the change 3.12 Degree On, Off DME-A602ABS SERIES can control the start phase angle (Degree On) or stop phase angle (Degree Off) of the output voltage waveform. Range for Degree On is 0.0~359.9, and is 0.0~360.0 for Degree Off.
  • Page 37 USER MANUAL A6000 AC POWER SOURCE 2. Change parameter to 100 by numerical key or knob rotating, then press confirm setting 3. Press to move cursor to Degree Off │ www.deltaww.com...
  • Page 38: Is Start, Is Interval

    USER MANUAL A6000 AC POWER SOURCE 4. Change parameter to 200 by numerical key or knob rotating, then press confirm the setting 3.13 Is Start, Is Interval Both the setting ranges for Is Start and Is Intervals are 0.0~1000.0 msec, these parameters are for the surge current measurement.
  • Page 39 USER MANUAL A6000 AC POWER SOURCE 1. Press to move cursor to Is Start 2. Change parameter to 500.0 by numerical key or knob, then press to confirm the change │ www.deltaww.com...
  • Page 40: Waveform Selection

    USER MANUAL A6000 AC POWER SOURCE 3. Press to move the cursor to Is Interval 4. Change parameter to 200 by numerical key or knob, then press to confirm the change 3.14 Waveform Selection Due to it needs time to do waveform calculation, DME-A602ABS SERIES provide A and B two sets built in waveforms.
  • Page 41 USER MANUAL A6000 AC POWER SOURCE 1. Press move to next page 2. Rotate knob to change <A> to <B>, press to confirm PS: Press at main manual, only A or B can be selected. If using List function, then A or B waveform can be output alternatively.
  • Page 42: Buzzer

    USER MANUAL A6000 AC POWER SOURCE 3.15 Buzzer When user press numerical key or rotate knob, there is sound from buzzer to confirm the operation, it can be muted if the confirmation is not needed. Following processes demonstrate how to mute the buzzer: 1.
  • Page 43: Disable (Lock) The Keys At Front Panel

    USER MANUAL A6000 AC POWER SOURCE 3.16 Disable (Lock) the Keys at Front Panel DME-A602ABS SERIES allow the user to lock the parameters at front panel to avoid being changed accidently. After the parameters are locked, only keys are enabled.
  • Page 44: Set Series / Parallel Output Mode

    USER MANUAL A6000 AC POWER SOURCE 3.16.1 Set Series / Parallel Output Mode DME-A602ABS SERIES provide two output modes:  Series: Two phase output voltages operate in series. Same voltage and frequency applies to both two phases output voltage.  Parallel: two phase output voltage operate in parallel.
  • Page 45: Config Function

    USER MANUAL A6000 AC POWER SOURCE 3. Press back to main manual, "Series" can be found on the top right of the main manual, the contents for the Meter Report also changed at bottom of the main manual. 3.17 CONFIG Function 1.
  • Page 46: Waveform A, B Generator

    USER MANUAL A6000 AC POWER SOURCE 2. Press enter CONFIG page Definitions for all parameters are listed as below: Setting Range Name of definition parameter Minimum Maximum Wave A Stored group A waveform Sin, C Sin, SQUA, DST0~DST31 Wave B...
  • Page 47 USER MANUAL A6000 AC POWER SOURCE  Square (Square)  30 sets built in waveforms (DST0~DST29): See appendix B for details.  2 sets user defined waveforms (DST30~DST31) Following processes demonstrate how to set group A waveform as built in waveform number 20: 1.
  • Page 48 USER MANUAL A6000 AC POWER SOURCE Following processes demonstrate how to set group B waveforms as cut sinusoidal waveform (Cut Sine) with CF 1.300: 1. Press to move cursor to Wave B 2. Rotate knob to change <SIN> to <CSIN>, press to confirm the change.
  • Page 49 USER MANUAL A6000 AC POWER SOURCE 3. Press to move cursor to CSIN CF 4. By pressing numerical key or rotating knob, change parameter to 1.300, press confirm the setting PS: for details of more DISwaveforms, please refer to Appendix B.
  • Page 50: Gpib, Rs232 Communication Setting

    USER MANUAL A6000 AC POWER SOURCE 3.19 GPIB, RS232 Communication Setting DME-A602ABS SERIES provide remote control operation, there are GPIB or RS232 interface for selection. Only one interface can be activated at the same time: Remote Controller Manual Remote Operation mode...
  • Page 51 USER MANUAL A6000 AC POWER SOURCE 2. By pressing numerical key or rotating knob to change parameter to 20, press confirm Example how to set RS232 Baud rate = 19200, Odd/Even parity check = (ODD): 1. Press to move cursor to RS232 Baud Rate...
  • Page 52 USER MANUAL A6000 AC POWER SOURCE 2. Rotate knob to change parameter from <9600> to <19200>, press to confirm 3. Press to move cursor to RS232 Parity │ www.deltaww.com...
  • Page 53: Inhibit Output By Remote Control Signal (Remote Inhibit)

    USER MANUAL A6000 AC POWER SOURCE 4. Rotate knob to change parameter from <NONE> to <ODD>, press to confirm the change 3.20 Inhibit Output by Remote Control Signal (Remote Inhibit) Remote Inhibit is a ”Active HIGH” TTL signal, high level is 5V, low level is 0V. Its signals send to 9 pin TTL signal connector (D-SUB) at back panel of the AC source.
  • Page 54 USER MANUAL A6000 AC POWER SOURCE  TRIG: TTL signal changes from HIGH→LOW, and keeps low longer than 1ms, DME- A602ABS SERIES turn off output, and stop detecting TTL signal, output stay at off state even TTL signal changes to high. User must press to resume output and enable TTL signal detecting.
  • Page 55: Power On State

    USER MANUAL A6000 AC POWER SOURCE 2. Rotate knob to change <OFF> to <TRIG>, press to confirm change 3.21 Power On State DME-A602ABS SERIES may set parallel or series operation mode or enable turn on output immediately next time after AC is on. Output voltage and frequency depend on stored parameter before AC input is turned off.
  • Page 56 USER MANUAL A6000 AC POWER SOURCE 2. Rotate knob to change <Off> to <On>, press to confirm the change 3. Press to move cursor to Phase Sel. │ www.deltaww.com...
  • Page 57: Protection

    USER MANUAL A6000 AC POWER SOURCE 4. By pressing numeric key or rotating knob to change parameter to Parallel, press to confirm the change 3.22 Protection DME-A602ABS SERIES provide software and hardware protections. DME-A602ABS SERIES will cut off output relay to turn off output and display protection status on screen when protection happens.
  • Page 58 USER MANUAL A6000 AC POWER SOURCE  Protections by hardware: Errors Status description AUX PG Fault AUX Power output abnormal D2A IC Fault Voltage / current detection IC malfunction D2A OCP Fault Over current for D2D Board D2A OPP Fault...
  • Page 59: Applications

    USER MANUAL A6000 AC POWER SOURCE 4. Applications 4.1 Introduction Other than stable AC voltage, DME-A602ABS SERIES also provide three kinds programmable dynamic output. Following paragraphs explain the definition of parameters and how to do the setting:  LIST mode: Let user to set 10 sets of user-defined voltage, frequency. Can make 10 different outputs consecutively.
  • Page 60 USER MANUAL A6000 AC POWER SOURCE 2. Press enter LIST page 3. Press may enter next page as below LIST mode provide 10 sets of programmable waveform (SEQ-0~SEQ-9). Output waveforms start from SEQ-0, then SEQ-1, SEQ-2… in orders until time parameter (Time) of SEQ-n being processed is 0 or SEQ-9 is finished outputting, then one List waveform output is completed.
  • Page 61 USER MANUAL A6000 AC POWER SOURCE Following are definitions for all parameters: Range Parameter Definition Count Execution times for one complete List waveform. 10000 When 0 is setting, output recycles endless until user press to stop. V Start Start voltage (V) 300.0...
  • Page 62 USER MANUAL A6000 AC POWER SOURCE Press enter Trigger page as below: Trigger ON/OFF is output switch for List waveform, output status is current output status. At this page, there are two modes: 1. To output List waveform Press to start output List waveform. Screen will show information as below during output is in process: │...
  • Page 63 USER MANUAL A6000 AC POWER SOURCE At this moment, there are three outcomes depend on user input or process status:  Press key will stop output and stay at Trigger page.  Press key will stop output and back to main manual.
  • Page 64 USER MANUAL A6000 AC POWER SOURCE LIST mode example: Use single phase parallel mode as example. Parameter setting: │ www.deltaww.com...
  • Page 65: Pulse Mode

    USER MANUAL A6000 AC POWER SOURCE Output waveform: 4.3 PULSE Mode 1. At advanced parameter setting page, press to select PULSE │ www.deltaww.com...
  • Page 66 USER MANUAL A6000 AC POWER SOURCE 2. Press to enter PULSE page PULSE mode lets user insert fixed period, programmed special waveform to output waveform set at main manual. Definition for all parameters are: Range Parameter definition Count How many times to output programmed Pulse 10000 waveform.
  • Page 67 USER MANUAL A6000 AC POWER SOURCE Select Go to Trigger Mode, press to do the setting. Screen shows information as below at trigger page: Trigger ON/OFF is switch to control on/off of programmed Pulse waveform, Output Status is current status. Operation procedures on this page is same as that explained in paragraph 4.2.
  • Page 68: Step Mode

    USER MANUAL A6000 AC POWER SOURCE Output waveform: 4.4 STEP Mode 1. At advanced parameters setting manual, press to select STEP │ www.deltaww.com...
  • Page 69 USER MANUAL A6000 AC POWER SOURCE 2. press enter STEP page Voltage and frequency are same for each step in STEP mode, but may be different for different steps. Definitions for all parameters are: Range Parameters Definition Count How many steps...
  • Page 70 USER MANUAL A6000 AC POWER SOURCE Select Go to Trigger Mode, press to enter Trigger page shown as below: Trigger ON/OFF is switch to turn on/off Step output, Output Status is current output status. Operation on this page is same as that in paragraph 4.2.
  • Page 71: Synthesis Self-Defined Waveform Mode

    USER MANUAL A6000 AC POWER SOURCE Output waveform: 4.5 SYNTHESIS Self-Defined Waveform Mode 1. At advanced parameters setting manual, press to select SYNTHESIS │ www.deltaww.com...
  • Page 72 USER MANUAL A6000 AC POWER SOURCE 2. Press key to enter SYNTHESIS page In SYNTHESIS self-defined waveform mode, voltage and frequency of fundamental waveform is sinusoidal defined at main manual. User can edit amplitude and phase angle of harmonic waveform up to 39 order of fundamental wave. Edit can be done by front panel or remote control.
  • Page 73 USER MANUAL A6000 AC POWER SOURCE When parameters for all orders are set, Press back to first page of SYNTHESIS setting, press to move cursor to "Save and Calculate", press to calculate and save the synthesized waveform to EEPROM. Screen shows as below:...
  • Page 74 USER MANUAL A6000 AC POWER SOURCE It takes about 8 seconds to do the calculation and saving. It will back to first page of SYNTHESIS when saving is completed. For protection purpose, amplitude for each order must not exceed limitation as below.
  • Page 75: Save And Recall Functions

    USER MANUAL A6000 AC POWER SOURCE 5. Save and Recall Functions 5.1 System parameter Save and Recall DME-A602ABS SERIES provides 4 set of memories for user to save and recall modified system information. User can back to default system setting easily any time by selecting default setting.
  • Page 76 USER MANUAL A6000 AC POWER SOURCE 2. Change save No. (1-4) to 1 by pressing numerical key or rotating knob, press to confirm, then screen will show information indicate data is saving. It takes about 20 seconds to save. 3. After saving is completed, screen will back to advanced parameters setting manual as below │...
  • Page 77: Recall System Setting

    USER MANUAL A6000 AC POWER SOURCE 5.3 Recall System Setting How to back to default factory settings: 1. At advanced parameters setting manual, long press for two seconds will enter recall system setting page. DEFAULT is the default factory settings.
  • Page 78: Remote Operation

    USER MANUAL A6000 AC POWER SOURCE 6. Remote operation 6.1 Introduction DME-A602ABS SERIES can be remotely controlled by GPIB or RS-232. GPIB interface is an 8-bit parallel data bus cooperate control line to manage communication. RS-232 transmits data seriously so communication speed is slower.
  • Page 79: Programming

    USER MANUAL A6000 AC POWER SOURCE Screen shown >REMOTE< when AC source is in remote control as below: 6.5 Programming All commands and responses are transferred in the form of ASCII code. Response must be received completely before sending a new command. Otherwise, error will occur due to message disorder.
  • Page 80: Basic Definition For Command

    USER MANUAL A6000 AC POWER SOURCE 6.9 Basic Definition for Command Construction of DME-A602ABS SERIES remote control command is based on tree system, every command must have a full path so instrument can receive it. Tree structure use " : " as node. Command or data at left side of node is in higher level while at right side is in detail level.
  • Page 81: Command For Remote Control

    USER MANUAL A6000 AC POWER SOURCE 6.10 Command for Remote Control 6.10.1 IEEE 488.2 Standard Command *ESE <n> Set flag mask of standard event status register. This command is for a register used for IEE488.2 defined standard events. It is used for flag mask or control enable.
  • Page 82: Instrument Commands

    USER MANUAL A6000 AC POWER SOURCE 6.11 Instrument Commands 6.11.1 FETCH and MEASURE Subsystem Differences between FETCH and MEASURE are: FETCH reads existing measurements value. Execution time is shorter because data is available immediately but the data may not be the newest. Instrument will send computer the next sampling data after receiving MEASURE command.
  • Page 83 USER MANUAL A6000 AC POWER SOURCE :VOLTage :AC? Query average AC Vrms Query phase 1 AC Vrms Query phase 2 AC Vrms Following examples explain FETCH and MEASURE command and returned parameter: FETCh:CURRent:AC? MEASure:CURRent:AC? Function : Query output total AC Irms.
  • Page 84 USER MANUAL A6000 AC POWER SOURCE FETCh:CURRent:CREStfactor:(1, 2)? MEASure:CURRent:CREStfactor:(1, 2)? Function : Query output current crest factor for each phase Example : FETCh:CURRent:CREStfactor:1? MEASure:CURRent:CREStfactor:2? Parameter returns: <NR2> FETCh:CURRent:INRush? MEASure:CURRent:INRush? Function : Query output total inrush current Example : FETCh:CURRent:INRush? MEASure:CURRent:INRush? Parameter returns: <NR2>...
  • Page 85 USER MANUAL A6000 AC POWER SOURCE FETCh:POWer:AC[:REAL]:(1, 2)? MEASure:POWer:AC[:REAL]:(1, 2)? Function : Query output real power for each phase Example : FETCh:POWer:AC:1? MEASure:POWer:AC:2? Parameter returns: <NR2> FETCh:POWer:AC:APParent? MEASure:POWer:AC:APParent? Function : Query total apparent power Example : FETCh:POWer:AC:APParent? MEASure:POWer:AC:APParent? Parameter returns: <NR2>...
  • Page 86: Output Subsystem

    USER MANUAL A6000 AC POWER SOURCE FETCh:POWer:AC:REACtive:(1, 2)? MEASure:POWer:AC:REACtive:(1, 2)? Function : Query reactive power for each phase Example : FETCh:POWer:AC:REACtive:1? MEASure:POWer:AC:REACtive:2? Parameter returns: <NR2> FETCh:VOLTage:AC? MEASure:VOLTage:AC? Function : Query average output voltage Vrms Example : FETCh:VOLTage:AC? MEASure:VOLTage:AC? Parameter returns: <NR2>...
  • Page 87: Source Subsystem

    USER MANUAL A6000 AC POWER SOURCE 6.11.3 SOURCE Subsystem Following are tree system for SOURCE command: [SOURce:] CURRent :LIMit Set (query) total output current limitation Irms :DELay Set (query) delay time to trigger over current protection :INRush :STARt Set (query) time to start to measure inrush current...
  • Page 88 USER MANUAL A6000 AC POWER SOURCE PULSE :VOLTage Set (query) PULSE AC voltage :FREQuency Set (query) PULSE frequency :SPHase Set (query) start phase angle of AC voltage of PULSE :COUNt Set (query) how many times to execute PULSE :DCYCle Set (query) output duration of PULSE waveform, cannot be...
  • Page 89 USER MANUAL A6000 AC POWER SOURCE [SOURce:]CURRent:INRush:STARt Function : Set (query) time to start measure inrush current : [SOURce:]CURRent:INRush:STARt? Example [SOURce:]CURRent:INRush:STARt 200.3 Parameter : <NR2> , effective range: 0.0~9000.0 (unit: msec) Parameter returns: <NR2> [SOURce:]CURRent:INRush:INTerval Function : Set (query) inrush current measurement time...
  • Page 90 USER MANUAL A6000 AC POWER SOURCE [SOURce:]FUNCtion:SHAPe:A:CF Function : Set (query) CF of the cut sin waveform in waveform buffer A. It is effective only when CSIN is selected for waveform buffer A. : [SOURce:]FUNCtion:SHAPe:A:CF? Example [SOURce:]FUNCtion:SHAPe:A:CF 1.234 Parameter : <NR2> , effective range: 1.200~1.414 Parameter returns: <NR2>...
  • Page 91 USER MANUAL A6000 AC POWER SOURCE [SOURce:]VOLTage:AC:2 Function : Query setting voltage of phase 2 output in series operation : [SOURce:]VOLTage:AC:2? Example Parameter : <NR2> , effective range: 0.0~150.0 (150V output range), 0.0~300.0 (300V output range) Parameter returns: <NR2> [SOURce:]VOLTage:LIMit:AC Function : Set (query) voltage limit.
  • Page 92 USER MANUAL A6000 AC POWER SOURCE [SOURce:]PHASe:ON Function : Set (query) waveform start phase angle set at main manual. : [SOURce:]PHASe:ON? Example [SOURce:]PHASe:ON 200 Parameter : <NR2> , effective range: 0~359 Parameter returns: <NR2> [SOURce:]PHASe:OFF Function : Set (query) waveform stop phase angle set at main manual.
  • Page 93 USER MANUAL A6000 AC POWER SOURCE [SOURce:]LIST:VOLTage:AC:STARt Function : Set (query) start voltage for 10 individual sequences in SERIES mode. : [SOURce:]LIST:VOLTage:AC:STARt? Example [SOURce:]LIST:VOLTage:AC:STARt 110 22.5 55.6 Parameter : <NR2>,…,<NR2> , effective range: 0.0~150.0 (low voltage range), 0.0~300.0 (high voltage range) Parameter returns: <NR1>,…,<NR2>...
  • Page 94 USER MANUAL A6000 AC POWER SOURCE [SOURce:]PULSe:VOLTage:AC Function : Set (query) AC voltage of PULSE output. : [SOURce:]PULSE:VOLTage:AC? Example [SOURce:]PULSE:VOLTage:AC 250.1 Parameter : <NR2> , effective range: 0.0~150.0 (low voltage range), 0.0~300.0 (high voltage range) Parameter returns: <NR2> [SOURce:]PULSe:FREQuency Function : Set (query) frequency of PULSE waveform.
  • Page 95 USER MANUAL A6000 AC POWER SOURCE [SOURce:]PULSe:PERiod Function : Set (query) total period of PULSE mode : [SOURce:]PULSE:PERiod? Example [SOURce:]PULSE:PERiod 600 Parameter : <NR1> , effective range: 2~16000000 (unit: msec) Parameter returns: <NR1> [SOURce:]STEP:VOLTage:AC Function : Set (query) start voltage for STEP mode.
  • Page 96 USER MANUAL A6000 AC POWER SOURCE [SOURce:]STEP:SPHase Function : Set(query) start phase angle at STEP mode. : [SOURce:]STEP:SPHase? Example [SOURce:]STEP:SPHase 80 Parameter : <NR2> , effective range: 0~359 Parameter returns: <NR2> [SOURce:]STEP:DWELl Function : Set (query) output duration for each step in STEP mode.
  • Page 97: Other Commands

    USER MANUAL A6000 AC POWER SOURCE [SOURce:]SYNThesis:PHASe Function : Set (query) phase for each order of harmonic waveforms. : [SOURce:]SYNThesis:PHASe? Example [SOURce:]SYNThesis:PHASe 100.5 20.8 60.5 77.8 Parameter : <NR2>,…,<NR2> , effective range: 0.0~359.9 Parameter returns: <NR2>,…,<NR2> 6.11.4 Other Commands Followings are other commands instruction, example and returned parameter:...
  • Page 98: Summary Of Commands

    USER MANUAL A6000 AC POWER SOURCE VERion:UI? Function : Query firmware version for UI. : VERion:UI? Example Parameter returns: S00E00 INSTrument:NSELect 1 | 2 Function : set specific output phase for responcing queries: : INSTrument:NSELect? Example Query which phase is set for query.
  • Page 99 USER MANUAL A6000 AC POWER SOURCE  Instrument command FETCh | MEASure :CURRent :AC? Query the total AC rms current Query the phase 1 AC rms current Query the phase 2 AC rms current :AMPLitude:MAXimum? Query the total peak current...
  • Page 100 USER MANUAL A6000 AC POWER SOURCE :INRush :STARt Set (query) time to start to measure inrush current :INTerval Set (query) inrush current measurement time FREQuency Set (query) frequency of output voltage FUNCtion :SHAPe Set (query) waveform buffer to A or B...
  • Page 101 USER MANUAL A6000 AC POWER SOURCE :END Set (query) stop frequency for 10 individual sequences in LIST mode. :DEGRee Set (query) start phase angle for 10 individual sequences in LIST mode. PULSE :VOLTage Set (query) AC voltage of PULSE mode...
  • Page 102: Appendix A Ttl Pin Assignment

    USER MANUAL A6000 AC POWER SOURCE Appendix A TTL Pin Assignment  9-PIN D-SUB female connector Pin number signal Remote Inhibit AC-ON GND GND FAULT-OUT Remote Inhibit:  OFF Disable remote inhibit output function.  LIVE AC source will turn off (turn on) output when TTL signal is low (high).
  • Page 103: Appendix B Built In Waveforms

    USER MANUAL A6000 AC POWER SOURCE Appendix B Built In Waveforms DST 0 Order Gain Phase 2.07 9.80 15.80 2.16 DST 1 Order Gain Phase 1.50 1.50 2.00 DST 2 Order Gain Phase 2.00 1.40 2.00 1.40 1.00 │ www.deltaww.com...
  • Page 104 USER MANUAL A6000 AC POWER SOURCE DST 3 Order Gain Phase 2.50 1.90 2.50 1.90 1.10 1.50 1.10 DST 4 Order Gain Phase 1.10 2.80 1.40 2.30 1.50 DST 5 Order Gain Phase 1.65 4.20 3.45 1.05 3.00 │ www.deltaww.com...
  • Page 105 USER MANUAL A6000 AC POWER SOURCE DST 6 Order Gain Phase 2.20 5.60 2.80 4.60 3.00 1.40 1.00 DST 7 Order Gain Phase 4.90 1.60 2.70 1.40 2.00 1.10 DST 8 Order Gain Phase 7.35 2.40 4.05 2.10 1.05 3.00 1.65...
  • Page 106 USER MANUAL A6000 AC POWER SOURCE DST 9 Order Gain Phase 9.80 3.20 5.40 1.20 2.80 1.40 4.00 2.20 1.40 1.40 1.60 1.40 DST 10 Order Gain Phase 17.75 │ www.deltaww.com...
  • Page 107 USER MANUAL A6000 AC POWER SOURCE DST 11 Order Gain Phase 21.25 DST 12 Order Gain Phase 24.50 DST 13 Order Gain Phase 2.30 9.80 15.80 2.50 │ www.deltaww.com...
  • Page 108 USER MANUAL A6000 AC POWER SOURCE DST 14 Order Gain Phase 1.15 4.90 7.90 1.25 DST 15 Order Gain Phase 2.45 3.95 DST 16 Order Gain Phase 11.00 180.0 4.05 2.00 180.0 1.30 │ www.deltaww.com...
  • Page 109 USER MANUAL A6000 AC POWER SOURCE DST 17 Order Gain Phase 7.17 3.42 180.0 0.80 DST 18 Order Gain Phase 8.11 3.48 180.0 1.00 DST 19 Order Gain Phase 9.38 3.44 180.0 1.15 │ www.deltaww.com...
  • Page 110 USER MANUAL A6000 AC POWER SOURCE DST 20 Order Gain Phase 2.06 180.0 1.77 1.62 180.0 1.23 0.91 180.0 0.54 0.51 0.53 180.0 DST 21 Order Gain Phase 3.08 180.0 2.72 2.43 180.0 1.97 1.41 180.0 0.86 0.62 180.0 0.73 0.77...
  • Page 111 USER MANUAL A6000 AC POWER SOURCE DST 22 Order Gain Phase 0.13 180.0 4.28 180.0 3.77 3.27 180.0 2.57 1.93 180.0 1.22 0.55 180.0 0.46 0.83 180.0 0.97 1.04 180.0 0.75 180.0 DST 23 Order Gain Phase 5.74 180.0 5.11 4.44...
  • Page 112 USER MANUAL A6000 AC POWER SOURCE DST 24 Order Gain Phase 7.35 180.0 6.60 5.74 180.0 4.57 3.41 180.0 2.16 1.04 180.0 0.74 1.35 180.0 1.64 1.73 180.0 1.56 1.24 180.0 DST 25 Order Gain Phase 3.41 2.55 9.22 7.68 0.90...
  • Page 113 USER MANUAL A6000 AC POWER SOURCE DST 26 Order Gain Phase 1.38 5.39 2.29 DST 27 Order Gain Phase 33.33 20.00 13.80 10.80 8.50 7.20 6.00 5.00 5.00 4.50 4.00 3.50 2.95 2.50 2.00 2.00 2.00 2.00 2.00 │ www.deltaww.com...
  • Page 114 USER MANUAL A6000 AC POWER SOURCE DST 28 Order Gain Phase 33.33 20.00 13.80 10.80 8.50 7.20 6.00 5.00 5.00 4.50 4.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 DST 29 Order Gain Phase 33.33 20.00 13.80 10.80 8.50 7.20...
  • Page 115 Delta Electronics Ltd. 3 Tungyuan Rd., Chungli Industrial Zone, Taoyuan City 32063 TEL:+886 3 4526107 Mail:Inquiry@deltaww.com...