Delta A6000 User Manual page 30

Table of Contents

Advertisement

USER MANUAL
A6000
AC POWER SOURCE
3. Press
Definitions for all parameters are listed as below:
Parameter
V Limit
I Limit
OCP Delay
Voltage Level
Voltage Sense
Degree On
Degree Off
Is Start
Is Interval
Waveform
Buzzer
Keylock
Phase Sel.
27
│ www.deltaww.com
back to previous page
Definition
Maximum voltage setting for all pages
Maximum output Irms
Delay time for over current protection
Output voltage range
Output voltage measurement point: AC
source output/ input of testing product
Start phase angle of output voltage
Stop phase angle of output voltage
Delay time to start measuring output
surge current
Duration to measure surge current
Output waveform set at main manual
Toggle switch for Buzzer
Lock settings at main manual
Output mode setting
Setting Range
Min
Max
0.0
150.0 / 300.0
0.0
64.0 / 32.0
0.0
9.0
150 V / 300 V
Volage Sense / Remote Sense
0
360
0
359
0.0
9000.0
0.0
9000.0
A / B
ON / OFF
ON / OFF
Parallel / Series
Unit
V
A
Sec
degree
degree
msec
msec