Delta A6000 User Manual page 90

Table of Contents

Advertisement

USER MANUAL
A6000
AC POWER SOURCE
[SOURce:]FUNCtion:SHAPe:A:CF
Function
Example
Parameter : <NR2> , effective range: 1.200~1.414
Parameter returns: <NR2>
[SOURce:]FUNCtion:SHAPe:B
Function
Example
Parameter : SINE | CSIN | DST<00~31> | SQUA
Parameter returns: SINE | CSIN | DST<00~31> | SQUA
[SOURce:]FUNCtion:SHAPe:B:CF
Function
Example
Parameter : <NR2> , effective range: 1.200~1.414
Parameter returns: <NR2>
[SOURce:]VOLTage:AC
Function
Example
Parameter : <NR2> , effective range: 0.0~150.0 (150V Voltage level),
Parameter returns: <NR2>
[SOURce:]VOLTage:AC:1
Function
Example
Parameter : <NR2> , effective range: 0.0~150.0 (150V output range),
Parameter returns: <NR2>
87
│ www.deltaww.com
: Set (query) CF of the cut sin waveform in waveform buffer A. It is effective
only when CSIN is selected for waveform buffer A.
: [SOURce:]FUNCtion:SHAPe:A:CF?
[SOURce:]FUNCtion:SHAPe:A:CF 1.234
: Set waveform for waveform buffer B.
: [SOURce:]FUNCtion:SHAPe:B?
[SOURce:]FUNCtion:SHAPe:B CSIN
: Set (query) CF of the cut sin waveform in waveform buffer B. It is effective
only when CSIN is selected for waveform buffer B.
: [SOURce:]FUNCtion:SHAPe:B:CF?
[SOURce:]FUNCtion:SHAPe:B:CF 1.234
: Set (query) output voltage Vrms for parallel mode operation
: [SOURce:]VOLTage:AC?
[SOURce:]VOLTage:AC 200.5
: Set (query) output voltage for phase 1 output in series operation
: [SOURce:]VOLTage:AC:1?
[SOURce:]VOLTage:AC:1 200.5
0.0~300.0 (300V Voltage level)
0.0~300.0 (300V output range)