12/13
Field settings table
Breadcrumb
Field code
Setting name
9.I
[C-07]
What is the unit control method in space operation?
9.I
[C-08]
Which type of external sensor is installed?
9.I
[C-09]
What is the required alarm output contact type?
9.I
[C-0A]
--
9.I
[C-0B]
--
9.I
[C-0C]
--
9.I
[C-0D]
--
9.I
[C-0E]
--
9.I
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
9.I
[D-01]
Contact type of preferential kWh rate PS installation?
9.I
[D-02]
Which type of DHW pump is installed?
9.I
[D-03]
Leaving water temperature compensation around 0°C.
9.I
[D-04]
Is a demand PCB connected?
9.I
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
9.I
[D-07]
Is a solar kit connected?
9.I
[D-08]
Is an external kWh meter used for power measurement?
9.I
[D-09]
Is an external kWh meter used for power measurement, kWh meter used for smart
grid or a gas meter for hybrid unit?
9.I
[D-0A]
--
9.I
[D-0B]
--
9.I
[D-0C]
--
9.I
[D-0D]
--
9.I
[D-0E]
--
9.I
[E-00]
Which type of unit is installed?
9.I
[E-01]
Which type of compressor is installed?
9.I
[E-02]
What is the indoor unit software type?
9.I
[E-03]
What is the number of backup heater steps?
9.I
[E-04]
Is the power saving function available on the outdoor unit?
9.I
[E-05]
Can the system prepare domestic hot water?
9.I
[E-06]
--
9.I
[E-07]
What kind of DHW tank is installed?
9.I
[E-08]
Power saving function for outdoor unit.
9.I
[E-09]
--
9.I
[E-0A]
Tank volume
9.I
[E-0B]
Is a bizone kit installed?
4P670987-1A - 2022.02
Range, step
Default value
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: Normally open
1: Normally closed
0
0
0
0
0
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
R/W
0: No
1: Active open
2: Active closed
3: Smart Grid
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
R/W
0: No
1: Pwr consmp ctrl
R/W
0: Forced off
1: As normal
R/W
0: No
1: Solar for DHW
2: Solar for DHW and SH
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8 1 pulse/m³ (gas monitoring)
9 10 pulse/m³ (gas monitoring)
10 100 pulse/m³ (gas monitoring)
0
2
0
0
0
R/O
0~5
0: LT split
R/O
1
R/W (*3)
0: Reversible (*3)
R/O (*4)
1: Heating only (*4)
R/O
0: no heater (*9)
(*6,*7,*8)
1: ext heater
R/W (*9)
2: 3V (*6)
3: 6V (*7)
4: 9W (*8)
R/O
0: No
1: Yes
R/O
0: No
1: Yes
1
R/W
0~8
0 OSO tank 150/180
1 FS with BUH
2 FS with BSH
3 OSO tank 200/250/300
4 Rotex without BSH (HYB)
5 Rotex with BSH
6 Third party tank for HYB
7 Third party tank, coil >= 1,05m²
8 Third party tank, coil >= 1,8m²
R/W
0: disabled
1: Enabled
1
R/O
30 (*1)
50 (*2)
R/W
0: Not installed
1: -
2: Bizone kit installed
(*6) EKECBUA3V_(*7) EKECBUA6V_(*8) EKECBUA9W_
Installer setting at variance with
default value
Date
Value
(*1) 300 Tank_(*2) 500 Tank_
(*3) *X*_(*4) *H*_(*5) *B*_
(*9) BUH less

Hide quick links: