Daikin EPRA10EAV3 Installer's Reference Manual page 101

Table of Contents

Advertisement

EPRA08~12EAV3+W1 + ETSH/X(B)12P30+50EF
Daikin Altherma 3 H MT ECH₂O
4P663478-1B – 2022.07
Without installed drainback solar kit (option)
1 Connect a hose with non-return valve (1/2") to the drainback connection.
2 Fill the storage tank until water spills from the spillover connection.
3 Remove the hose.
a
b
a Drainback connection
b Spillover connection
c Hose with non-return valve (1/2")
With installed drainback solar kit (option)
1 Combine the fill and drain kit (option) with the drainback solar kit (option) to
fill the storage tank.
2 Connect the hose with non-return valve to the fill and drain kit.
Follow the steps described in the previous chapter.
b
8
Piping installation
|
c
a
Installer reference guide