Daikin EPRA10EAV3 Installer's Reference Manual page 298

Table of Contents

Advertisement

10/13
Field settings table
Breadcrumb
Field code
Setting name
9.I
[4-08]
Which power limitation mode is required on the system?
9.I
[4-09]
Which power limitation type is required?
9.I
[4-0A]
Backup heater configuration
9.I
[4-0B]
Automatic cooling/heating changeover hysteresis.
9.I
[4-0D]
Automatic cooling/heating changeover offset.
9.I
[4-0E]
--
9.I
[5-00]
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
9.I
[5-01]
What is the equilibrium temperature for the building?
9.I
[5-02]
Space heating priority.
9.I
[5-03]
Space heating priority temperature.
9.I
[5-04]
Set point correction for domestic hot water temperature.
9.I
[5-05]
What is the requested limit for DI1?
9.I
[5-06]
What is the requested limit for DI2?
9.I
[5-07]
What is the requested limit for DI3?
9.I
[5-08]
What is the requested limit for DI4?
9.I
[5-09]
What is the requested limit for DI1?
9.I
[5-0A]
What is the requested limit for DI2?
9.I
[5-0B]
What is the requested limit for DI3?
9.I
[5-0C]
What is the requested limit for DI4?
9.I
[5-0D]
Backup heater voltage
9.I
[5-0E]
--
9.I
[6-00]
The temperature difference determining the heat pump ON temperature.
9.I
[6-01]
The temperature difference determining the heat pump OFF temperature.
9.I
[6-02]
What is the capacity of the booster heater?
9.I
[6-03]
What is the capacity of the backup heater step 1?
9.I
[6-04]
What is the capacity of the backup heater step 2?
9.I
[6-07]
--
9.I
[6-08]
What is the hysteresis to be used in reheat mode?
9.I
[6-09]
--
9.I
[6-0A]
What is the desired comfort storage temperature?
9.I
[6-0B]
What is the desired eco storage temperature?
9.I
[6-0C]
What is the desired reheat temperature?
9.I
[6-0D]
What is the desired DHW production type?
9.I
[6-0E]
What is the maximum temperature setpoint?
9.I
[7-00]
Domestic hot water booster heater overshoot temperature.
9.I
[7-01]
Domestic hot water booster heater hysteresis.
9.I
[7-02]
How many leaving water temperature zones are there?
9.I
[7-03]
--
9.I
[7-04]
--
9.I
[7-05]
Boiler efficiency
9.I
[7-06]
Compressor forced OFF
9.I
[7-07]
BBR16 activation*
*BBR16 settings are only visible when the language of the user interface is set to
Swedish.
9.I
[7-08]
DHW stratification
4P670987-1A - 2022.02
Range, step
Default value
R/W
0: No limitation
1: Continuous
2: Digital inputs
3: Load Monitor
R/W
0: Current
1: Power
R/W (*7,
0: 1 (*6, *9)
*8, *9)
1: 1/1+2 (*7, *8)
R/O (*6)
2: 1/2
3: 1/2 + 1/1+2 in emergency
R/W
1~10°C, step: 0,5°C
1°C
R/W
1~10°C, step: 0,5°C
3°C
R/O
6
R/W
0: No
1: Yes
R/W
-15~35°C, step: 1°C
0°C
R/W
0: Disabled
1: Enabled
R/W
-15~35°C, step: 1°C
0°C
R/W
0~20°C, step: 1°C
10°C
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/O
0: 230V, 1~ (*6, *7, *9)
2: 400V, 3~ (*8)
1
R/W
2~40°C, step: 1°C
8°C
R/W
0~10°C, step: 1°C
0°C
R/W
0~10kW, step: 0,2kW
0kW
R/W
0~10kW, step: 0,2kW
0kW
2kW (*7)
3kW (*6, *8, *9)
R/W (*7,
0~10kW, step: 0,2kW
*8)
0kW (*6)
R/O (*6,
3kW (*9)
*9)
4kW (*7)
6kW (*8)
0
R/W
2~20°C, step: 1°C
10°C
0
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
0: Reheat only
3 scheduled reheat
R/W
[E-07]=4
40~ 75°C, step: 1°C
65°C
R/W
0~4°C, step: 1°C
0°C
R/W
2~40°C, step: 1°C
2°C
R/W
0: 1 LWT zone
1: 2 LWT zones
2,5
0
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
R/W
0: Disabled
1: Enabled
R/W
0: Disabled
1: Enabled
R/W
0: Disabled (*2)
1: Enabled (*1)
(*6) EKECBUA3V_(*7) EKECBUA6V_(*8) EKECBUA9W_
Installer setting at variance with
default value
Date
Value
(*1) 300 Tank_(*2) 500 Tank_
(*3) *X*_(*4) *H*_(*5) *B*_
(*9) BUH less