9e (Cumulative Numbers)
9f (ACK of Downlink Command)
06 (Set Threshold Alarm)
Example:
1. Set reporting interval as 20 minutes.
Channel
ff
03 (Set Reporting Interval)
2. Reboot the device.
Channel
ff
3. Set the device as standard mode.
Channel
ff
71 (Set Device Mode)
2 Bytes,
Byte 1: 00 = Disable; 01 = Enable
Byte 2: Cumulative numbers
00 = Disable; 01 = Enable
9 Bytes,
CTRL(1B)+Min(2B)+Max(2B)+00000000 (4
B)
CTRL:
Bit2~Bit0:
000-disable
001-below
010-above
011-within
100-below or above
Bit5~Bit3:
001-Standard Mode
010-Bin Mode
Bit6=0
Bit7:
0 - disable threshold dismiss report
1 - enable threshold dismiss report
ff03b0040000
Type
b0 04 00 00 => 00 00 04 b0 = 1200s = 20
ff10ff
Type
10 (Reboot)
ff7100
Type
Value
minutes
Value
ff (Reserved)
Value
00 = Standard Mode
26