70 (Set Height Threshold in
Parking Lot Mode)
77 (Set Installation Height)
Example:
1. Set reporting interval as 20 minutes.
Channel
ff
03 (Set Reporting Interval)
2. Reboot the device.
Channel
ff
3. Set the device as standard mode.
Channel
ff
71 (Set Device Mode)
4. Enable "Tilt & Distance Switch" feature.
Channel
ff
3e (Set Tilt & Distance Switch)
Bit2~Bit0:
000-disable
001-below
010-above
011-within
below or above
Bit5~Bit3:
001-Standard Mode
010-Bin Mode
Bit6=0
Bit7:
0 - disable threshold dismiss report
1 - enable threshold dismiss report
2 Bytes, unit: mm
2 Bytes, unit: mm
ff03b004
Type
ff10ff
Type
10 (Reboot)
ff7100
Type
ff3e01
Type
Value
b0 04 => 04 b0 = 1200s = 20 minutes
Value
ff (Reserved)
Value
00 = Standard Mode
Value
01 = Enable
21