Starting Problems (continued)
Problem
Engine cranks, but does not start.
Engine cranks (but should not) with the traction pedal
out of the neutral position.

General Run Problems

Problem
Battery does not charge.
Engine kills during operation.
Multi Pro 5600
Possible Causes
Ignition switch is faulty.
Engine is malfunctioning (see Chapter 3 – Ford
Gasoline Engine).
Fuel system is malfunctioning (see Chapter 3 – Ford
Gasoline Engine).
Engine may be too cold.
Neutral switch is out of adjustment or faulty.
Neutral switch wiring is faulty (see Chapter 8 –
Electrical Diagrams).
Possible Causes
Wiring to the charging circuit components is loose,
corroded, or damaged (see Chapter 8 – Electrical
Diagrams).
Alternator belt is slipping or damaged.
Alternator is faulty.
Battery is dead.
Ignition switch is faulty.
Engine is malfunctioning (see Chapter 3 – Ford
Gasoline Engine).