NOTE: If suction tube in tank develops an air leak, spray
performance will diminish when tank level reaches the
leak.
1
Removal (Fig. 30)
IMPORTANT: Make sure to remove and neutralize
chemicals from tank and spray components before
disassembly. Wear protective clothing, chemical re-
sistant gloves, and eye protection during repair.
1. Park machine on a level surface, stop engine, en-
gage parking brake, and remove key from the ignition
switch.
2. Remove suction strainer from spray tank (see Oper-
ator's Manual).
Figure 31
1. Suction strainer location
3. Raise tank lid and remove strainer basket to gain ac-
cess to suction tube inside spray tank.
4. Remove suction tube assembly from spray tank and
disassemble tube using Figure 13 as a guide. Discard
all removed o–rings and gaskets.
Assembly (Fig. 30)
NOTE: Coat all o–rings with vegetable oil before instal-
lation to reduce the chance of damage during assembly.
1. Assemble and install suction tube assembly using
Figure 30 as a guide. Replace all removed o–rings and
gaskets.
2. Check spray tank for leaks.