Ruijie RG-AP180P-L Hardware Installation And Reference Manual page 15

Table of Contents

Advertisement

Hardware Installation and Reference Guide
Table 1-8
LED Status
LED Color
Off
Steady
green
Steady red
Blinking red
Blinking green
Blinking green
Blinking red
Table 1-9
Reset Button
Button
Reset button
Frequency
Description
Possible cases:1. The AP is not powered on. 2. The AP is powered on,
N/A
but the LED is manually turned off.
N/A
The software system of the AP is being initialized.
N/A
The system is running properly, but the uplink service port is down.
On for 3s
In fit mode, the CAPWAP tunnel between the AP and AC timed out.
Off for 1s
On for 0.2s
In fit or MACC mode, the software system of the AP is being upgraded
and the AP cannot be powered off.
Off for 0.2s
On for 3s
The software system runs properly, and the CAPWAP tunnel status is
normal.
Off for 1s
On for 0.2s
In fit mode, the AP is being located.
Off for 0.2s
Operation
Result
Press the button
Restart the device.
for less than 2s
Press and hold
the button for
Restore to factory settings.
longer than 5s
9