Raystar 112LP (SeaTalk version)

To connect your Raystar 112LP to your Chartplotter or Combined Radar/
Chartplotter, refer to the first illustration below or follow the instructions in
Chapter 8.
To connect the Raystar 112LP and your Differential Beacon Receiver, cut off
the 5-pin connector and strip back the red, black and green wires. Remove the
sleeve from the end of the Raystar 112LP cable to expose the green and brown
wires, then connect to the Auxiliary Junction Box as shown in the second
illustration below.
CAUTION
Ensure the correct polarity of the 12 V supply before applying display or
SeaTalk power. It is recommended that a multimeter is used to check the
connections.
To Display Unit
SeaTalk Socket
Black
12V
Power
Supply
Red
(fused)
To Display Unit
SeaTalk Socket
Black
12V
Power
Supply
(fused)
Red
HSB Series LCD Display
Screen
From
Red
GPS
Yellow
sensor
D4292-3
Screen
Red
From
Yellow
GPS
Green
sensor
Brown
Black
White
From
Red
the
Green
DBR
Yellow
D4296-3