Raymarine DSM30 Installation Manual

Raymarine DSM30 Installation Manual

Raymarine digital sounder module installation manual dsm300, dsm30

Advertisement

DSM300 & DSM30
Digital Sounder
Module

Installation Manual

Document number: 87080-1
Date: November 2006

Advertisement

Table of Contents
loading

Summary of Contents for Raymarine DSM30

  • Page 1: Installation Manual

    DSM300 & DSM30 Digital Sounder Module Installation Manual Document number: 87080-1 Date: November 2006...
  • Page 2: Trademarks And Registered Trademarks

    Trademarks and registered trademarks HSB, Raymarine and SeaTalk are registered trademarks of Raymarine plc. All other product names are trademarks or registered trademarks of their respective owners. Contents of this handbook ©Raymarine 2006...
  • Page 3: Table Of Contents

    Contents Trademarks and registered trademarks ... 2 Important Information ...5 Intended Use ... 5 Safety Notices ... 5 EMC Conformance ... 6 Declaration of Conformity ... 6 Product Disposal ... 6 Waste Electrical and Electronic Equipment (WEEE) Directive ... 6 Warranty ...
  • Page 4 2.4 How to Contact Raymarine ...28 On the Internet ...28 Customer Support ...28 In the US ...28 Accessories and Parts ...28 Technical Support ...29 Product Repair and Service ...29 In Europe ...30 Technical Support ...30 Accessories and Parts ...30 Worldwide Support ...30 Appendix: Specifications...31...
  • Page 5: Important Information

    CAUTION: Transducer Cable Removing the transducer cable from the rear of the DSM300 or DSM30 while the sounder module is powered on can cause sparks. Only remove the transducer cable after power has been removed from the DSM. As with any electronic device, be sure the sounder module is mounted where it is well ventilated and free from gasoline fumes.
  • Page 6: Emc Conformance

    Declaration of Conformity Raymarine plc declare that the DSM300 and DSM30 Digital Sounder Modules are in compliance with the essential requirements of EMC directive 2004/108/EC. The original Declaration of Conformity certificate may be viewed on the relevant product page at www.raymarine.com.
  • Page 7: Chapter 1: Dsm Installation

    Chapter 1: DSM Installation 1.1 Introduction This chapter provides details for mounting the DSM300 and DSM30 and connecting to the display. For the system to display depth, water temperature and speed, you must install the transducer type(s) capable of transmitting the appropriate data.
  • Page 8: Suppression Ferrites

    Raymarine equipment. Always use the ferrites supplied by Raymarine. Connections to Other Equipment If your Raymarine equipment is to be connected to other equipment using a cable not supplied by Raymarine, a suppression ferrite must always be attached to the cable that is closest to the Raymarine unit.
  • Page 9: Unpacking And Inspecting The Components

    DSM300 Digital Sounder Module, DSM300 & DSM30 Installation Manual Installation Manual, part no. 87080 DSM30 Digital Sounder Module, C Series Network Cable, 3m DSM300 part no. E63069 DSM300 Operation Manual Operation Manual for PLUS Displays, part no.
  • Page 10: Cable Options

    3-pin configuration. This requires that you use a 4-pin to 3-pin adapter (Raymarine part number R69081) when connecting a sounder module to an hsb This adapter is included with the DSM300 but must be ordered separately with a DSM30. Select from the following cable options:...
  • Page 11: Mounting The Sounder Module

    Chapter 1: DSM Installation • Interference: The selected location should be far enough away from devices that may cause interference, such as motors, generators, and radio transmitter/receivers. (See the EMC guidelines earlier in this chapter.) • Magnetic compass: Mount the unit at least 3 ft (1 m) away from a magnetic compass.
  • Page 12 1. Hold the module in the location where you want to mount it, making sure it is perpendicular to the deck. 2. Mark the location of the four key holes onto the mounting surface. 3. Drill a 9/64" pilot hole at each of the marked locations. DSM300 and DSM30 Installation Manual D7479-1 D7538-1...
  • Page 13 Chapter 1: DSM Installation Note: For fiberglass with a gelcoat surface, you should overdrill the surface to prevent the gelcoat from chipping when driving in the screw. Before drilling the pilot hole, hand drill the marked location with an oversized bit and countersink to approximately 3/8" diame- ter.
  • Page 14: Cable Runs

    To protect exposed pins, please place the attached dust cover over the socket (4-pin or RJ-45) to which you are not connecting a cable. DSM300 and DSM30 Installation Manual PLUS Series display 10.7 to 32 VDC (DSM300), 10.7 to 18 VDC (DSM30)
  • Page 15: Transducer Connection

    The DSM300 is intended for use on boat’s DC power systems rated from 10.7 V to 32 V. The DSM30 is intended for use on boat’s DC power systems rated from 10.7 V to 18 V (12 volt systems only).
  • Page 16 You should locate the DSM so that the power cord can be easily removed, if necessary. If the sounder is placed in a difficult-to-reach location, Raymarine strongly suggests installing an on/off switch on the DSM power cord at a point where it is easily accessible.
  • Page 17 Chapter 1: DSM Installation Sounder Module C Series Display Unit Power Supply Transducer Power Connections with a C Series Display Sounder Module Power Supply hsb PLUS Series Display Unit Transducer Power Connections with an hsb PLUS Series Display...
  • Page 18: Ground Connection

    When the DSM is used with a single display, connection is made via a SeaTalk Crossover Coupler. Sounder Module Configuring an E Series System - Single Display DSM300 and DSM30 Installation Manual PLUS Series, C Series or E Series display Crossover Coupler E55060 SeaTalk hs Cable network.
  • Page 19: Configuring C Series Displays

    The C Series system uses cables with a round 4-pin twist-lock network connector. A 3m-long C Series cable is included with your sounder module and is also available in a 10 m length (Raymarine part number E65011). The display cable attaches to the 4-pin male connector labelled “HSB2”on the connector panel of the sounder module.
  • Page 20: Configuring Hsb2 Plus (Pathfinder) Series Displays

    Sounder Module 4-pin to 3-pin R69081 adapter 3-pin hsb Configuring an hsb DSM300 and DSM30 Installation Manual PLUS (Pathfinder) Series Displays PLUS Series display, connect the supplied 4-pin to network. You must not use an inline adapter R58117 3-pin to 3-pin hsb...
  • Page 21: Chapter 2: Maintenance And Problem Solving

    Chapter 2: Maintenance and Problem Solving Chapter 2: Maintenance and Problem Solving This chapter provides information on routine maintenance and on possible causes of problems you may experience with your Digital Sounder Module. 2.1 Maintenance CAUTION: The sounder unit contains high voltage. Adjustments require specialized service procedures and tools only available to qualified service technicians.
  • Page 22: Emc Servicing And Safety Guidelines

    EMC Servicing and Safety Guidelines • Raymarine equipment should be serviced only by authorized Raymarine ser- vice technicians. They will ensure that service procedures and replacement parts used will not affect performance. There are no user serviceable parts in any Raymarine product.
  • Page 23: Resetting The System

    Chapter 2: Maintenance and Problem Solving 2.2 Resetting the System The Reset function returns the sounder module to its factory default values. How you perform the reset depends on the type of display the sounder module is connected to. CAUTION: Factory Reset The factory reset clears the sonar depth offset and speed and temperature calibrations.
  • Page 24 DSM300 and DSM30 Installation Manual iii. An audible alarm is sounded. iv. The normal sonar image resumes scrolling across the display. The reset is complete. To cancel the reset: Before pressing YES as described in item 4 above, press any of the following keys: DISPLAY, MULTI, VRM/EBL, MARKS, RANGE, GAIN, or ALARMS.
  • Page 25: Problem Solving

    Chapter 2: Maintenance and Problem Solving 2.3 Problem Solving All Raymarine products are, prior to packing and shipping, subjected to comprehensive test and quality assurance programs. However, if this unit should develop a fault, please refer to the following table to identify the most likely cause and the corrective action required to restore normal operation.
  • Page 26: Status Led

    1.5 secs, blinks amber twice 0.5 secs apart, pauses 1.5 secs, and then repeats the sequence until the problems are resolved or up to 10 minutes elapse. DSM300 and DSM30 Installation Manual Correction 1. If necessary, adjust the TEMP CALIBRATE parameter.
  • Page 27 A solid red LED (not blinking) indicates a fatal error condition. If the event of a fatal error, the system will power cycle to attempt to self-correct the condition. If the condition persists, please contact Raymarine Customer Service. No of...
  • Page 28: How To Contact Raymarine

    If the answer you are seeking is not available, click the Ask Raymarine tab to submit your own question to our technical support staff, who will reply to you by e-mail.
  • Page 29: Technical Support

    Questions can be sent directly to our Technical Support Department via the Internet. Point your browser to www.raymarine.com and click on the Customer Support link. From there, select Find Answers and click the Ask Raymarine tab. Product Repair and Service In the unlikely event your Raymarine unit should develop a problem, please contact your authorized Raymarine dealer for assistance.
  • Page 30: In Europe

    Installation chapter of this manual and have the Raymarine part number ready when speaking with your dealer. If you are uncertain about what item to choose for your Raymarine unit, please contact our Customer Services Department prior to placing your order.
  • Page 31: Appendix: Specifications

    Appendix: Specifications Appendix: General Approvals: CE - conform to Size: Weight: Mounting: Power: Voltage: DSM300: DSM30: Current: Fuse: Environmental: Operating Range: Storage Range: Humidity: Connectors: Sounder Features Output Power: Frequency: Pulse Length: Max. Transmit Rate: 1580 pulses / min. @ 50’ range 1580 pulses / min. @ 50’ range...
  • Page 32 DSM300 and DSM30 Installation Manual...
  • Page 33: Index

    E Series displays Connections 16 Servicing & Safety Guidelines 22 Error codes 26 Factory Reset 23 Ground Connections 18 Help from Raymarine 28 High Voltage 5 HSB2 Connector 14 hsb2 PLUS Series displays Connections 17 Installation 7 Cable Runs 14...
  • Page 34 Transducer Cleaning 21 Connections 14 Warning codes 26 Warranty 6 DSM300 and DSM30 Installation Manual...

This manual is also suitable for:

Dsm300

Table of Contents