Technical Specifications
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
When determining cable lengths, make sure the nominal input voltage for the power
supply is provided at the power source.
Power
Supply Type
Minimum
LO
10 VDC
HI
88 VDC
85 VAC
a
Current consumption may vary based on configuration.
5.2
Failsafe Alarm Relay Specifications
Maximum Switching Voltage
a
50 to 60 Hz for 1 minute
5.3
Supported Networking Standards
The following networking standards are supported by RUGGEDCOM RSG909R:
Standard
IEEE 802.3x
RUGGEDCOM RSG909R
Installation Manual, 04/2023, C79000-G8976-1388-17
Input Voltage
Maximum
Nominal
60 VDC
12 VDC, 24
VDC, 48 VDC
300 VDC
125 VDC,
250 VDC
264 VAC
110 VAC,
220 VAC
Switching
30 VDC
125 VDC
300 VDC
250 VAC
10 Mbps
100 Mbps
Ports
Ports
Internal
Fuse Rating
5 A
3.15 A
3.15 A
Rated
Current
a
2 A
5.0 kVAC
between coil and contacts
a
0.48 A
1.0 kVAC
between contacts
0.2 A
2 A
1000 Mbps Ports
5
Isolation
Maximum
Power
Consumption
1.5 kVDC
13.4 W
5 kVDC
15.3 W
5 kVDC
15.5 W
Isolation
Notes
Full Duplex Operation
a
31