Delayed Egress
Exit Device
Installation Instructions
7
Installing Delayed Egress Exit Device
Refer to Figure 6 for delayed egress exit device installation wiring.
NOTE: For ElectroLynx Hinge Connector System: Follow Section 6 wiring instructions.
For non-ElectroLynx door:
Remove connector at end of exit device and connect to incoming wires from power source using
wire nuts, butt splices, etc. See Section 9 for hole locations and sizes.
8 6 4 2
7 5 3 1
White (NO Sec)
Green (NC Sec)
Orange (NO Alarm)
Blue (NC Alarm)
Brown (Remote Reset)
Yellow (Remote Bypass)
Red + 2
Black - 1
Green (NC Sec) 4
White (NO Sec) 3
Blue (NC Alarm) 6
Orange (NO Alarm) 5
Yellow (Remote Bypass) 8
Brown (Remote Reset) 7
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Red +
Black -
with 8-Pin Connector
(Provided with exit device)
8 6 4 2
7 5 3 1
Raceway Harness with
8 & 4-Pin Connectors
(4-pin connectors are
not shown and are not
used)
Figure 6
Pigtail Harness
4
3
9
Electric Hinge
with 8-Pin Connectors
Exit Device Connector
1
2
Note: Typical raceway location
is shown. Other locations may
exist depending on door type.