Commissioning

10.1.1 System requirements

58
───
NOTICE
Check and update software version
The automatic securing of the end positions of the electric cylin-
der requires the following TwinCAT 3 Drive Manger  2 software
version:
TE5910 | Version 1.1.44.0 or higher
Product defect possible, as the end positions may not be se-
cured.
• Check the software status of TwinCAT 3 Drive Manger 2.
• Update to the required version.
NOTICE
Check and update firmware version
The automatic securing of the end positions of the electric cylin-
der requires the following firmware version of the servo drive:
AX8000 | axis module FW 1.05 Build 8 or higher
AX5000 | servo drive FW 2.15 or higher
Risk of defect. The end positions may not be secured.
• Check the firmware version of the servo drive
• Update to the required version
TE5950 setup download
You can find the current setup file on the product website
TE5950 | TwinCAT 3 Drive Manager 2