11-3),even when in another menu, except programming menus, indicating that another LOC is requesting ECS
Control. The piezo buzzer on the LOC with ECS Control sound when an ECS Control request is active to alert a
nearby operator of the request.
Figure 11-3 ECS Control Request on LOC with ECS Control
Once ECS Control is passed to another LOC, the new user will assume the system AS IS. This means that the
event that was set to be playing at the previous LOC and all output areas it was playing in do not change.
11.2.8

Exit ECS Control Menu

The user can exit the LOC ECS interface by pressing the left arrow. The user will be returned to the idle screen
which indicates that the LOC still has ECS control.
11.2.9

Relinquish ECS Control

Relinquishing ECS Control is accomplished by pressing the ECS Control Key from within Message Mode or
Microphone Mode. A screen will be displayed to ensure the user wants to relinquish ECS Control. ECS Control
will be automatically relinquished after a time-out on this screen. When ECS Control is relinquished, the system
stays in the Manual ECS State. ECS Control can then be gained by another LOC or again at the same LOC.

11.2.10 ECS Reset

An ECS reset is accomplished by pressing the RESET button from an LOC. The user will be prompted to reset
either the fire system or emergency system. After an ECS reset, the LOC will automatically exit the LOC ECS
interface.
Note: In order to perform an ECS reset, the display must be associated with the ECS-VCM / ECS-RVM. See Sec-
tion 11.6.2.2.

11.3 ECS Super User

The ECS Super User access code profile function provides the ability to override all ECS Control rules and gain
ECS Control. The ECS Super User is the highest priority user in the system. The ECS Super User has several
features that differ from the normal user:
1.
Any alarm activated while under ECS Super User Control needs to be reset using an ECS Super User func-
tion enabled access code.
2.
LOC priority and LOC lockout timer are ignored when passing ECS Control between ECS Super Users at
LOCs. If another ECS Super User attempts to gain ECS Control from an LOC, an ECS Control request is
presented to the ECS Super User at the LOC that currently has ECS Control.
Figure 11-4 Relinquish ECS Control Screen
11-6
Emergency Communication System Operation