List of IDP SLC Devices

The following IDP SLC devices can be used with the control panel. See the device installation instructions
(packaged with the device) for more information.
Note: The control panel supports the use of either IDP SLC devices or SD SLC devices. You cannot install both
SLC device types on the control panel.
Part Numbers
IDP-Photo
IDP-Photo-T
IDP-Acclimate
IDP-PhotoR
IDP-Beam
IDP-Beam-T
DNR/DNRW
IDP-Heat
IDP-Heat-ROR
IDP-Heat-HT
IDP-Pull-SA
IDP-Pull-DA
IDP-ISO
ISO-6
IDP-Monitor
IDP-Minimon
IDP-Monitor-2
IDP-Monitor-10
IDP-Relay
IDP-Relay-6
IDP-RelayMon-2
IDP-Zone
IDP-Zone-6
IDP-Control
IDP-Control-6
IDP-FIRE-CO
B200S/IV
B200SR/IV
7-1
Caution!
Model Name/Description
Photoelectric smoke detector
Photoelectric smoke detector with thermal (135°F)
Multi-criteria photoelectric smoke detector with thermal (135°F)
Photoelectric replacement smoke detector with remote test capability in DNR I56-3569-000
Reflected beam smoke detector without test feature
Reflected beam smoke detector with test feature
Duct smoke detector housing. Non-relay (photo sold separately)
Fixed temperature thermal detector (135°F)
Rate-of-rise thermal detector with 135° fixed temperature
Fixed high temperature thermal detector (190°F)
Addressable single action pull station
Addressable dual action pull station
Fault isolator module
Six Fault isolator module
Monitor module
Mini monitor module
Dual input monitor module
10 input monitor module
Relay module
Six circuit relay module
Multi module with 2 relay outputs & 2 monitor inputs
Zone interface module
Six zone interface module
Supervised control module
Six circuit supervised control module
CO Smoke Detector
Intelligent sounder base. White or Ivory
Intelligent sounder base. White or Ivory
151430-L8
Installation
Sheet PN
I56-3611-000
I56-2735-00
I56-3051-000
I56-3608-000
I56-3606-000
I56-3605-000
I56-2729-000
I56-4096-000
I56-3603-000
I56-2726-002
I56-2730-000
I56-2731-000
I56-2729-000
I56-2729-000
I56-3734-000
I56-3602-000
I56-2733-000
I56-3600-000
I56-2734-000
I56-3946-00
I56-3387-00
I56-3392-00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Farenhyt ifp-2000ecsFarenhyt rps-2000

Table of Contents