IGSMV / IGSMVCN Installation and Setup Guide

PROMPTS
Enter Password
6
Verify Password
7
Exit Prog. Mode?
8
(Y/N)_
Device Mode
9
(ECP)_
NOTE: In order for the Multi Mode, Multi Mode Addr, and Remote Access programming fields to appear an account
must be created in the AlarmNet Direct website and "Remote Access" must be enabled for the comm device.
Users can receive email notification of system events by using the Multi-Mode feature. In ECP mode, this is
accomplished through emulation of a 4204 relay module, or two 4204 relay modules. When "4204-sourced" is
selected, the user can be notified of up to four events, plus two additional events if using the optional
communication device zones of 6 and 7. When "2-4204-sourced" is selected, the user can be notified of up to eight
system events. The Multi-Mode address must match the address of a relay module enabled in the control panel
(although you don't actually connect a module). If using "2-4204-sourced," the address of the second module is
automatically assigned the next device address after the first 4204. Make sure that address is also enabled in the
control panel. Program outputs to trigger on system events the user would like to be notified of through Output
Device (Relay) programming in the control panel.
These events are configured at the AlarmNet Total Connect website at: https://services.alarmnet.com/TotalConnect
U L / ULC
Multi Mode
10
(Disabled)_
Multi Mode Addr
11
(12)_
3-4
ENTRY
[0-9, A-F, N, S,
T, X, Y]
[0-9, A-F, N, S,
T, X, Y]
[Y], [N]
[ESC]
 ECP
 Zone Triggers
 4204 Emu
 Two 4204s
Important Information Regarding Multi-Mode Options
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace
Central Station reporting of critical events (alarms, troubles, etc.).
Multi-Mode has not been evaluated by UL or ULC.
 Disabled
 4204 Sourced
 2-4204 Sourced
[01-30]
OPTIONS
This prompt is displayed if [Y] was pressed in Prompt
4 or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog.
Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed
directly.
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode paragraph in
this section.
Press [ENTER] to select ECP mode.
Press the [space] key to scroll through choices.
Use Table 3-4 if selecting other choices.
Enable if you want system events sent by email to the
user.
Select "4204 Sourced" to send up to four events (plus
two additional reports triggered by optional hardwire
zones 6 and 7), or "2-4204 Sourced" to send eight
events.
Disable for normal alarm processing and go to Prompt
12: "Primary City ID".
This address must be programmed if using the Multi-
Mode (email notification) feature. The device address
must be unique from the normal LRR Device Address
(Prompt 19) and the Keypad Address used for Remote
Access or Direct Wire downloading. The address used
must also be enabled as a 4204 relay module in Vista
and First Alert control panels.
See Important Information above.