ADIC SNC 6101 Installation And Maintenance Manual page 26

Quantum snc 6101: user guide
Hide thumbs Also See for SNC 6101:
Table of Contents

Advertisement

2
On your computer, double-click the HyperTerminal icon (Start> Program> Accessories>
Communications> HyperTerminal).
3
In the New Connection dialog box, enter SNC6101 for a name (any name will do) and click OK.
4
In the Connect To dialog box for the Connect using field, select the COM port your computer will be
using (COM1, for example) and click OK.
5
In the COM Properties dialog box, select these values:
Bits per second
Data bits
Parity
Stop bits
Flow control
Emulation
Refer to your HyperTerminal documentation for any additional information
Note
on how to configure and run HyperTerminal.
6
Click OK.
To configure the SNC 6101
1
Power up the Scalar 100 and wait until the startup initialization process completes.
Within a few minutes, the RDY LED on the SNC 6101 will start flashing once per second and the Done
executing startup script message will appear on your service terminal.
To ensure proper initialization of the SNC 6101, allow at least one
CAUTION
minute between a Scalar 100 power-down and subsequent power-up.
2
At the service terminal, initialize the SNC 6101 by typing initializeBox.
SNC 6101 commands are case sensitive. Always enter capital and lower case
Note
characters as indicated.
Use initializeBox only for a new or a replacement SNC 6101. This
CAUTION
command resets the fibre and SCSI channels, clears the device map
and the event log, and disables all enabled features.
22
19200
8
None
1
None
ANSI
Installation