Keysight Technologies U9361G Quick Start Manual
Keysight Technologies U9361G Quick Start Manual

Keysight Technologies U9361G Quick Start Manual

Receiver calibrator
Hide thumbs Also See for U9361G:

Advertisement

Quick Links

Keysight Technologies
U9361C/F/G/M Receiver Calibrator
Quick Start
Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the U9361G and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight Technologies U9361G

  • Page 1 Keysight Technologies U9361C/F/G/M Receiver Calibrator Quick Start Guide...
  • Page 2 The information contained in this document is subject to change without notice. Keysight Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3: Table Of Contents

    What You Will Find in this Document What You Will Find in this Document Where to Find the Latest Information..................ESD Information ........................Protection from Electrostatic Discharge ..............Handling of Electronic Components and ESD ............For Additional Information about ESD ................
  • Page 4: Where To Find The Latest Information

    URLs, according to the name of your product: http://www.keysight.com/find/u9361c http://www.keysight.com/find/u9361f http://www.keysight.com/find/u9361g http://www.keysight.com/find/u9361m To receive the latest updates by email, subscribe to Keysight Email Updates at the following URL: https://support.keysight.com...
  • Page 5: Esd Information

    ESD Information ESD Information Protection from Electrostatic Discharge Electrostatic discharge (ESD) can damage or destroy electronic components. All work on electronic assemblies should be performed at a static-safe workstation. Figure 1 shows an example of a static-safe workstation using two types of ESD protection: —...
  • Page 6: Handling Of Electronic Components And Esd

    ESD Information Handling of Electronic Components and ESD The possibility of unseen damage caused by ESD is present whenever components are transported, stored, or used. The risk of ESD damage can be greatly reduced by paying close attention to how all components are handled. —...
  • Page 7: Overview

    Inspect the shipping container and the cushioning material for signs of stress. Retain the shipping materials for future use, as you may wish to ship the instrument to another location or to Keysight Technologies for service. Figure 2 Shipping Case...
  • Page 8: Shipping Problems

    — Contact the nearest Keysight Technologies office. — Keep the shipping materials for the carrier’s inspection. — If you must return the calibrator to Keysight Technologies, use the original (or comparable) shipping materials. See “Returning a U9361C/F/G/M Receiver Calibrator for Service” on...
  • Page 9: Calibrators Covered By This Guide

    — U9361F: 10 MHz to 50 GHz Receiver Calibrator, 2.4 mm RF out connector — U9361G: 10 MHz to 67 GHz Receiver Calibrator, 1.85 mm RF out connector — U9361M: 10 MHz to 110 GHz Receiver Calibrator, 1.0 mm RF out connector...
  • Page 10 Calibrators Covered by This Guide Figure 3 Calibrator Rear View U9361C/F/G/M Receiver Calibrator Quick Start Guide...
  • Page 11: Operation

    Operation Operation Operating Precautions Do not exceed the maximum ratings listed below or permanent damage to the calibrator will result. Electrostatic discharge When connecting the U9361C/F/G/M USB cable, always connect the USB-A end of the cable to the receiver (signal analyzer) BEFORE connecting the USB-C end of the cable to the calibrator unit.
  • Page 12: Instrument Information

    Operation Instrument Information Environmental Conditions The U9361C/F/G/M Receiver Calibrator is designed for indoor use and in an area with low condensation. The table below shows the general environmental requirements for this instrument. Environmental Condition Requirement Temperature Operating condition, 0 °C to 55 °C Storage condition, –40 °C to 70 °C Maximum Relative Humidity Operating condition...
  • Page 13 Operation This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canada. The product may have some performance loss that may cause the signal to dropout or lose communication when exposed to ESD events when tested per IEC 61000-4-2.
  • Page 14: Regulatory Markings

    Operation Regulatory Markings The table below lists the definitions of markings that may be on or with the product. The CE marking is a registered trademark of the European Community. It indicates that the product complies with all relevant directives. The UK conformity mark is a UK government owned mark.
  • Page 15 Operation The affixed product label is as shown below. Do not dispose in domestic household waste. To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml for more information. U9361C/F/G/M Receiver Calibrator Quick Start Guide...
  • Page 16: Setup Procedure

    Operation Setup Procedure During a calibration process, the calibrator, the product being calibrated, or it’s associated connections, should not to be touched or disturbed. ESD could cause signal to drop out or lose communication. Verify host analyzer has software revision A.30.08 or later. On the analyzer press System, Show System.
  • Page 17 Operation Figure 4 Typical Setup Configuration U9361C/F/G/M Receiver Calibrator Quick Start Guide...
  • Page 18: Led Definition

    LED Definition LED Definition The Receiver Calibrator has three LEDs; Status, RF Out and 10 MHz Ref, that signal the state of the calibrator. See chart below for information on how to interpret the LEDs. Table 4-1 Troubleshooting procedure RCal State Status RF Out 10MHz Ref...
  • Page 19: Example: Rcal Calibration Using A Uxa Signal Analyzer

    Example: RCal Calibration Using a UXA Signal Analyzer Example: RCal Calibration Using a UXA Signal Analyzer The calibration procedure detailed below is specific to using a U9361 RCal with a UXA signal analyzer. Since the RCal is designed to use in various configurations it is important for the user to refer to their specific instrument calibration documentation for detailed requirements regarding adapters, cables, settings, and procedure.
  • Page 20 Example: RCal Calibration Using a UXA Signal Analyzer Procedure On the analyzer select Mode/Meas > Spectrum Analyzer Mode > Swept SA Measurement. Then, press Mode Preset. Select: Input/Output > Calibration > Configuration. This should bring up the RCal Configuration table: Press Select Calibrator, and replace None with RCal Module 1.
  • Page 21 Example: RCal Calibration Using a UXA Signal Analyzer The table should now appear as shown below: By using the scroll bar below the row, you can view the right side of the table: If the parameters shown in the examples above do not match your configuration, manually adjust the system to match.
  • Page 22 Example: RCal Calibration Using a UXA Signal Analyzer Press the Calibrate Checked Rows button. You should see the following message: With the RCal module connected to the signal path, press OK to start the calibration: When the calibration completes, you should (briefly) see the message below: The table column “Last Calibrated”...
  • Page 23 Example: RCal Calibration Using a UXA Signal Analyzer To apply the correction, check the “Apply” column in the row. The table should appear as: The “Applied” column should show “Yes”, indicating that the selected calibration is being applied. For more detailed information, press the RCal Status button to bring up the status page: The status for this Cal Group and Row is Calibration Status “Calibrated”...
  • Page 24: Care And Maintenance

    Care and Maintenance Care and Maintenance Disconnect the Keysight U9361C/F/G/M from USB power before cleaning. Use a dry cloth or one slightly dampened with water to clean the external case parts. Do not attempt to clean internally. The U9361C/F/G/M receiver calibrator is not field-repairable, and requires return to Keysight for both repair and calibration.
  • Page 25 Care and Maintenance Connector Contacts Inspect the connector contacts for integrity. It is necessary to use good lighting (such as a halogen task light) to see the contacts. Notice the location of the cross hairs in relationship to the center of the figures. Contact Integrity Refer to the following for visual guidelines when evaluating the contact integrity of a connector.
  • Page 26: Making Connections

    Care and Maintenance Male Connector: Making Connections Good connections require a skilled operator. Instrument sensitivity and coaxial connector mechanical tolerances are such that slight errors in operator technique can have a significant effect on measurements and measurement uncertainties. The most common cause of measurement error is poor connections. 1.
  • Page 27 Care and Maintenance Connection Procedure Familiarize yourself with the proper use of the double-ended torque wrench shown in Figure 5 below. To prevent expensive repairs and repair downtime, take a few minutes to study the information in the following pages. Figure 5 Dual Torque wrench, 14 mm open end, 4 lb-in (0.45 Nm) and 10 lb-in (1.13 Nm), Part Number 8710-2819...
  • Page 28 Care and Maintenance Output Port Adapters Ruggedized adapter: — 1 mm to 1.00 mm Y1900B/C/D adapter This adapter can be connected to the U9361M output port. Due to the physical requirements needed to obtain high performance, the geometry of these, as well as all, 1 mm connectors, demands special care to avoid expensive damage as explained in this document.
  • Page 29 Care and Maintenance Hold the torque wrench lightly at the groove located at the end of the handle. Apply force perpendicular to the wrench handle. This applies torque to the connection through the wrench. Do not hold the wrench so tightly that you push the handle straight down along its length rather than pivoting it, otherwise you apply an unlimited amount of torque.
  • Page 30 Care and Maintenance Applying Torque For the 1 mm Output Port connector, use the dual torque wrench. For matching non-ruggedized connectors using the inner threads, to the U9361M, use the 4 lb-in torque wrench. Two wrenches must be used to avoid stress on semi-rigid cables. Figure 8 Wrenches on Test Port Direction to...
  • Page 31 Care and Maintenance Selecting and Positioning the Wrenches For a few possible connections, the following figures show the proper “flats” on which to place the wrench. Ruggedized Adapter to 1 mm Output Port Figure 9 shows the correct placement of the 10 lb-in torque wrench (the red end) and the 8 mm open end wrench.
  • Page 32 Care and Maintenance Adapter to 1 mm Output Port (without ruggedized adapter) It is recommended that you always connect a ruggedized adapter to the U9361M output port. However, if you want to connect an adapter that uses the inner threads, or cable directly to a test port connector, use the 4 lb-in end of the dual torque wrench (silver end of the dual torque wrench).
  • Page 33: Cleaning Connectors

    Care and Maintenance Cleaning Connectors 1. Inspect the connectors for dust, dirt, metal fragment, oils or film, and debris. 2. Blow off any dust with a filtered, clean supply of compressed air. 3. Add a few drops of high-purity isopropyl alcohol to a small cleaning swab (do not apply alcohol directly to the parts).
  • Page 34: Returning A U9361C/F/G/M Receiver Calibrator For Service

    Returning a U9361C/F/G/M Receiver Calibrator for Service Returning a U9361C/F/G/M Receiver Calibrator for Service Contacting Keysight Assistance with test and measurement needs and information or finding a local Keysight office are available on the Web at: http://www.keysight.com/find/assist If you do not have access to the Internet, contact your field engineer. In any correspondence or telephone conversation, refer to the Keysight product by its model number and full serial number.
  • Page 35 This information is subject to change without notice. © Keysight Technologies 2020-2021 Edition 1, October 2021 U9361-90001 www.keysight.com...