Daikin Altherma ERLQ004CAV3 Installer's Reference Manual page 101

Hide thumbs Also See for Altherma ERLQ004CAV3:
Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
User settings
└─ Preset values
└─ Room temperature
7.4.1.1
Comfort (heating)
7.4.1.2
Eco (heating)
└─ LWT main
7.4.2.1
[8-09]
Comfort (heating)
7.4.2.2
[8-0A]
Eco (heating)
7.4.2.5
Comfort (heating)
7.4.2.6
Eco (heating)
└─ Tank temperature
7.4.3.1
[6-0A]
Storage comfort
7.4.3.2
[6-0B]
Storage eco
Reheat
7.4.3.3
[6-0C]
└─ Quiet level
7.4.4
Installer settings
└─ System layout
└─ Standard
A.2.1.1
[E-00]
Unit type
A.2.1.2
[E-01]
Compressor type
A.2.1.3
[E-02]
Indoor software type
A.2.1.4
[E-03]
Backup heater steps
A.2.1.5
[5-0D]
BUH type
A.2.1.6
[D-01]
Preferential kWh rate
A.2.1.7
[C-07]
Unit control method
A.2.1.8
[7-02]
Number of LWT zones
A.2.1.9
[F-0D]
Pump operation mode
A.2.1.A
[E-04]
Power saving possible
A.2.1.B
User interface location
└─ Options
A.2.2.1
[E-05]
DHW operation
A.2.2.3
[E-07]
DHW tank heater
A.2.2.4
[C-05]
Contact type main
A.2.2.5
[C-06]
Contact type add.
A.2.2.6.1
[C-02]
Digital I/O PCB
A.2.2.6.2
[D-07]
Digital I/O PCB
A.2.2.6.3
[C-09]
Digital I/O PCB
A.2.2.6.4
[F-04]
Digital I/O PCB
A.2.2.7
[D-04]
Demand PCB
A.2.2.8
[D-08]
External kWh meter 1
A.2.2.9
[D-09]
External kWh meter 2
A.2.2.A
[D-02]
DHW pump
A.2.2.B
[C-08]
External sensor
└─ Capacities
A.2.3.2
[6-03]
BUH: step 1
Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1
LWT setpoint mode
A.3.1.1.2.1
[9-01]
Temperature range
A.3.1.1.2.2
[9-00]
Temperature range
A.3.1.1.3
[1-00]
Set weather-dependent heating
A.3.1.1.3
[1-01]
Set weather-dependent heating
EHVH0*S18CA3VF
Ext. backup heat src
Solar kit
Alarm output
Bottom plate heater
Minimum temp (heating)
Maximum temp (heating)
Low ambient temp. for LWT main zone heating
WD curve.
High ambient temp. for LWT main zone heating
WD curve.
Range, step
Default value
R/W
[3-07]~[3-06], step: A.3.2.4
21°C
R/W
[3-07]~[3-06], step: A.3.2.4
19°C
R/W
[9-01]~[9-00], step: 1°C
35°C
R/W
[9-01]~[9-00], step: 1°C
33°C
R/W
-10~10°C, step: 1°C
0°C
R/W
-10~10°C, step: 1°C
-2°C
R/W
30~80°C, step: 1°C
60°C
R/W
30~50°C, step: 1°C
45°C
R/W
30~50°C, step: 1°C
45°C
R/W
0: Level 1
1: Level 2
2: Level 3
R/O
0: LT split
R/O
0:08
R/O
1: Type 2
R/O
1: 1 step
R/W
1: 1P,(1/1+2)
R/W
0: No
1: Active open
2: Active closed
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: 1 LWT zone
1: 2 LWT zones
R/W
0: Continuous
1: Sample
2: Request
R/O
1: Yes
R/W
0: At unit
1: In room
R/W
1: Yes
R/W
1: Backup heater
R/W
0: -
1: Thermo ON/OFF
2: C/H request
R/W
0: -
1: Thermo ON/OFF
2: C/H request
R/W
0: No
1: Bivalent
2: -
3: -
R/W
0: No
R/W
0: Normally open
1: Normally closed
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0~10kW, step: 0,2kW
3kW
R/W
0: Absolute
1: Weather dep.
2: Abs + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~55°C, step: 1°C
55°C
R/W
-20~5°C, step: 1°C
-10°C
R/W
10~20°C, step: 1°C
15°C
3/8
Installer setting at variance with
default value
Date
Value
4P366223-1 - 2014.02