6 Preparation
6.4
Preparing electrical wiring
6.4.1
About preparing electrical wiring
WARNING
▪ If  the  power  supply  has  a  missing  or  wrong  N­phase,
equipment will break down.
▪ Establish  proper  earthing.  Do  NOT  earth  the  unit  to  a
utility  pipe,  surge  absorber,  or  telephone  earth.
Incomplete earthing may cause electrical shock.
▪ Install the required fuses or circuit breakers.
▪ Secure  the  electrical  wiring  with  cable  ties  so  that  the
cables do NOT come in contact with the piping or sharp
edges, particularly on the high­pressure side
▪ Do  NOT  use  taped  wires,  stranded  conductor  wires,
extension  cords,  or  connections  from  a  star  system.
They can cause overheating, electrical shock or fire.
▪ Do  NOT  install  a  phase  advancing  capacitor,  because
this  unit  is  equipped  with  an  inverter.  A  phase
advancing  capacitor  will  reduce  performance  and  may
cause accidents.
WARNING
▪ All  wiring  must  be  performed  by  an  authorized
electrician  and  must  comply  with  the  applicable
legislation.
▪ Make electrical connections to the fixed wiring.
▪ All  components  procured  on  the  site  and  all  electrical
construction  must  comply  with  the  applicable
legislation.
6.4.3
Overview of electrical connections except external actuators
Normal power supply
a
0
0
58 0
1 5 0
3
1
2
a
Normal power supply
b
Preferential kWh rate power supply
1
Power supply for outdoor unit
2
Power supply and interconnection cable to indoor unit
3
Power supply for backup heater
4
Preferential kWh rate power supply (voltage free contact)
5
Normal kWh rate power supply (to power the indoor unit PCB in the event of power supply interruption of the preferential kWh rate power supply)
6.4.4
Overview of electrical connections for
external and internal actuators
Installer reference guide
24
6.4.2
Electricity  companies  throughout  the  world  work  hard  to  provide
reliable  electric  service  at  competitive  prices  and  are  often
authorized  to  bill  clients  at  benefit  rates.  E.g.  time­of­use  rates,
seasonal rates, Wärmepumpentarif in Germany and Austria, ...
This  equipment  allows  for  connection  to  such  preferential  kWh  rate
power supply delivery systems.
Consult  with  the  electricity  company  acting  as  provider  at  the  site
where  this  equipment  is  to  be  installed  to  know  whether  it  is
appropriate to connect the equipment in one of the preferential kWh
rate power supply delivery systems available, if any.
When  the  equipment  is  connected  to  such  preferential  kWh  rate
power supply, the electricity company is allowed to:
▪ interrupt power supply to the equipment for certain periods of time;
▪ demand  that  the  equipment  only  consumes  a  limited  amount  of
electricity during certain periods of time.
The  indoor  unit  is  designed  to  receive  an  input  signal  by  which  the
unit switches into forced off mode. At that moment, the outdoor unit
compressor will not operate.
Whether the power supply is interrupted or not, the wiring to the unit
is different.
Preferential kWh rate power supply
Power supply is NOT interrupted
b
0
0
58 0
1 5 0
3
4
2
During preferential kWh rate power supply
activation, power supply is NOT interrupted.
The outdoor unit is turned off by the control.
Remark: The electricity company must always
allow the power consumption of the indoor
unit.
The following illustration shows the required field wiring.
WARNING
The backup heater should have a dedicated power supply.
WARNING
ALWAYS use multicore cable for power supply cables.
About preferential kWh rate power supply
Power supply is interrupted
a
0
0
58 0
1 5 0
1
5
During preferential kWh rate power supply
activation, power supply is interrupted
immediately or after some time by the
electricity company. In this case, the indoor
unit must be powered by a separate normal
power supply.
ERLQ004~008CA + EHVH04+08S18CA3VF
Daikin Altherma low temperature split
b
0
0
58 0
1 5 0
3
4
1
2
4P366226­1 – 2014.01