Daikin Altherma ERLQ004CAV3 Installer's Reference Manual page 103

Hide thumbs Also See for Altherma ERLQ004CAV3:
Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
└─ Auto restart
A.6.1
[3-00]
└─ Preferential kWh rate
A.6.2.1
[D-00]
Allowed heaters
A.6.2.2
[D-05]
Forced pump OFF
└─ Pwr consumpt. Control
A.6.3.1
[4-08]
Mode
A.6.3.2
[4-09]
Type
A.6.3.3
[5-05]
Amp. value
A.6.3.4
[5-09]
kW value
A.6.3.5.1
[5-05]
Amp. limits for DI
A.6.3.5.2
[5-06]
Amp. limits for DI
A.6.3.5.3
[5-07]
Amp. limits for DI
A.6.3.5.4
[5-08]
Amp. limits for DI
A.6.3.6.1
[5-09]
kW limits for DI
A.6.3.6.2
[5-0A]
kW limits for DI
A.6.3.6.3
[5-0B]
kW limits for DI
A.6.3.6.4
[5-0C]
kW limits for DI
A.6.3.7
[4-01]
Priority
└─ Averaging time
A.6.4
[1-0A]
└─ Ext amb. sensor offset
A.6.5
[2-0B]
└─ Overview settings
A.8.1
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
A.8.2
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
A.8.3
[0-02]
High ambient temp. for LWT add zone heating WD curve.
A.8.4
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
A.8.5
[0-04]
--
A.8.6
[0-05]
--
A.8.7
[0-06]
--
A.8.8
[0-07]
--
A.8.9
[0-0B]
Leaving water value for high ambient temp. for DHW WD curve.
A.8.10
[0-0C]
Leaving water value for low ambient temp. for DHW WD curve.
A.8.11
[0-0D]
High ambient temp. for DHW WD curve.
A.8.12
[0-0E]
Low ambient temp. for DHW WD curve.
A.8.13
[1-00]
Low ambient temp. for LWT main zone heating WD curve.
A.8.14
[1-01]
High ambient temp. for LWT main zone heating WD curve.
A.8.15
[1-02]
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
A.8.16
[1-03]
Leaving water value for high ambient temp. for LWT main zone heating WD curve. R/W
A.8.17
[1-04]
--
A.8.18
[1-05]
--
A.8.19
[1-06]
--
A.8.20
[1-07]
--
A.8.21
[1-08]
--
A.8.22
[1-09]
--
A.8.23
[1-0A]
What is the averaging time for the outdoor temp?
A.8.24
[2-00]
When should the disinfection function be executed?
A.8.25
[2-01]
Should the disinfection function be executed?
A.8.26
[2-02]
When should the disinfection function start?
A.8.27
[2-03]
What is the disinfection target temperature?
A.8.28
[2-04]
How long must the tank temperature be maintained?
A.8.29
[2-05]
Room antifrost temperature
A.8.30
[2-06]
Room frost protection
EHVH0*S18CA3VF
Limit DI1
Limit DI2
Limit DI3
Limit DI4
Limit DI1
Limit DI2
Limit DI3
Limit DI4
Range, step
Default value
R/W
0: No
1: Yes
R/W
0: None
2: BUH only
R/W
0: Forced off
1: As normal
R/W
0: No limitation
1: Continuous
2: Digital inputs
R/W
0: Current
1: Power
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0: None
1: BSH
2: BUH
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
R/W
-5~5°C, step: 0,5°C
0°C
R/W
25~55°C, step: 1°C
35°C
R/W
25~55°C, step: 1°C
45°C
R/W
10~20°C, step: 1°C
15°C
R/W
-20~5°C, step: 1°C
-10°C
R/W
8
R/W
12
R/W
35
R/W
20
R/W
35~55°C, step: 1°C
55°C
R/W
55~70°C, step: 1°C
70°C
R/W
10~20°C, step: 1°C
15°C
R/W
-20~5°C, step: 1°C
-10°C
R/W
-20~5°C, step: 1°C
-10°C
R/W
10~20°C, step: 1°C
15°C
R/W
25~55°C, step: 1°C
35°C
25~55°C, step: 1°C
25°C
R/W
0: Disabled
R/W
0: Disabled
R/W
20
R/W
35
R/W
22
R/W
18
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0: No
1: Yes
R/W
0~23 hour, step: 1 hour
23
R/W
60°C
R/W
40~60 min, step: 5 min
60 min
R/W
4~16°C, step: 1°C
12°C
R/W
0: Disabled
1: Enabled
5/8
Installer setting at variance with
default value
Date
Value
4P366223-1 - 2014.02

Hide quick links:

Advertisement

Table of Contents