Synchronization
Data difference detected.
Please select action:
Send data
Adjust
Confirm
5 Select the required action:
▪ Send data: the user interface you are operating contains the
correct data and the data on the other user interface will be
overwritten.
▪ Receive data: the user interface you are operating does
NOT contain the correct data and the data on the other user
interface will be used to overwrite.
6 The user interface requests confirmation if you are sure to
proceed.
Start copy
Are you sure you want to
start the copy operation?
OK
Cancel
Confirm
Adjust
7 Confirm the selection on the screen by pushing
(languages, schedules etc.) will be synchronised from the
selected source user interface to the other one.
INFORMATION
▪ During the copying, both controllers display Busy and
will NOT allow operation.
▪ The copy operation can take up until 90 minutes.
▪ It is recommended to change installer settings, or the
configuration itself, on the main user interface.
8 Your system is now set to be operated by the 2 user interfaces.
8.1.4
To copy the language set from the first to
the second user interface
See "8.1.4 To copy the system settings from the first to the second
user interface" on page 43.
8.1.5
Quick wizard: Set the system layout after
first power ON
After first power ON of the system, you are guided on the user
interface to do initial settings:
▪ language,
▪ date,
▪ time,
▪ system layout.
By confirming the system layout, you can proceed with the
installation and commissioning of the system.
1 At power ON, the quick wizard starts as long as the system
layout was NOT confirmed yet, by setting the language.
Language
Select the desired language
Confirm
Adjust
ERLQ004~008CA + EHVH04+08S18CA3VF
Daikin Altherma low temperature split
4P3662261 – 2014.01
2 Set the current date and time.
What is the current time?
Confirm
3 Set the system layout settings: Standard, Options, Capacities.
For more details, see "8.2 Basic configuration" on page 43.
A.2
Standard
Options
Capacities
Confirm layout
Select
4 Confirm by pressing
Please confirm the system
layout. The system will
restart and will be ready for
first startup.
OK
and all data
Confirm
5 The user interface reinitialises and you can proceed the
installation by setting the other applicable settings and
commissioning of the system.
When the installer settings are changed, the system will request to
confirm. When confirmation is complete, the screen will shortly turn
OFF and "busy" will be displayed for several seconds.
8.2
Basic configuration
8.2.1
Quick wizard: Language / time and date
#
[A.1]
[1]
8.2.2
Quick wizard: Standard
Space heating settings
The system can heat up a space. Depending on the type of
application, the space heating settings must be made accordingly.
#
[A.2.1.7]
8 Configuration
Time
00
: 00
Adjust
Scroll
System layout
1
Scroll
.
Confirm layout
Cancel
Adjust
Code
Description
N/A
Language
N/A
Time and date
Code
Description
[C07]
Unit control method:
▪ 0 (LWT control): Unit operation is
decided based on the leaving water
temperature regardless the actual
room temperature and/or heating
demand of the room.
▪ 1 (Ext RT control): Unit operation is
decided by the external thermostat or
equivalent (e.g. heat pump convector).
▪ 2 (RT control): Unit operation is
decided based on the ambient
temperature of the user interface.
Installer reference guide