To Copy The Language Set From The First To The Second User Interface; Quick Wizard: Set The System Layout After First Power On; Basic Configuration; Quick Wizard: Language / Time And Date - Daikin Altherma ERLQ004CAV3 Installer's Reference Manual

Hide thumbs Also See for Altherma ERLQ004CAV3:
Table of Contents

Advertisement

Synchronization
Data difference detected.
Please select action:
Send data
Adjust
Confirm
5 Select the required action:
▪ Send data: the user interface you are operating contains the
correct data and the data on the other user interface will be
overwritten.
▪ Receive  data:  the  user  interface  you  are  operating  does
NOT contain the correct data and the data on the other user
interface will be used to overwrite.
6 The  user  interface  requests  confirmation  if  you  are  sure  to
proceed.
Start copy
Are you sure you want to
start the copy operation?
OK
Cancel
Confirm
Adjust
7 Confirm the selection on the screen by pushing 
(languages,  schedules  etc.)  will  be  synchronised  from  the
selected source user interface to the other one.
INFORMATION
▪ During  the  copying,  both  controllers  display  Busy  and
will NOT allow operation.
▪ The copy operation can take up until 90 minutes.
▪ It  is  recommended  to  change  installer  settings,  or  the
configuration itself, on the main user interface.
8 Your system is now set to be operated by the 2 user interfaces.
8.1.4
To copy the language set from the first to
the second user interface
See "8.1.4 To copy the system settings from the first to the second
user interface" on page 43.
8.1.5
Quick wizard: Set the system layout after
first power ON
After  first  power  ON  of  the  system,  you  are  guided  on  the  user
interface to do initial settings:
▪ language,
▪ date,
▪ time,
▪ system layout.
By  confirming  the  system  layout,  you  can  proceed  with  the
installation and commissioning of the system.
1 At  power  ON,  the  quick  wizard  starts  as  long  as  the  system
layout was NOT confirmed yet, by setting the language.
Language
Select the desired language
Confirm
Adjust
ERLQ004~008CA + EHVH04+08S18CA3VF
Daikin Altherma low temperature split
4P366226­1 – 2014.01
2 Set the current date and time.
What is the current time?
Confirm
3 Set  the  system  layout  settings:  Standard,  Options,  Capacities.
For more details, see "8.2 Basic configuration" on page 43.
A.2
Standard
Options
Capacities
Confirm layout
Select
4 Confirm by pressing 
Please confirm the system
layout. The system will
restart and will be ready for
first startup.
OK
 and all data
Confirm
5 The  user  interface  re­initialises  and  you  can  proceed  the
installation  by  setting  the  other  applicable  settings  and
commissioning of the system.
When  the  installer  settings  are  changed,  the  system  will  request  to
confirm. When confirmation is complete, the screen will shortly turn
OFF and "busy" will be displayed for several seconds.
8.2
Basic configuration
8.2.1
Quick wizard: Language / time and date
#
[A.1]
[1]
8.2.2
Quick wizard: Standard
Space heating settings
The  system  can  heat  up  a  space.  Depending  on  the  type  of
application, the space heating settings must be made accordingly.
#
[A.2.1.7]
8 Configuration
Time
00
: 00
Adjust
Scroll
System layout
1
Scroll
.
Confirm layout
Cancel
Adjust
Code
Description
N/A
Language
N/A
Time and date
Code
Description
[C­07]
Unit control method:
▪ 0  (LWT  control):  Unit  operation  is
decided  based  on  the  leaving  water
temperature  regardless  the  actual
room  temperature  and/or  heating
demand of the room.
▪ 1  (Ext  RT  control):  Unit  operation  is
decided  by  the  external  thermostat  or
equivalent (e.g. heat pump convector).
▪ 2  (RT  control):  Unit  operation  is
decided  based  on  the  ambient
temperature of the user interface.
Installer reference guide
43

Hide quick links:

Advertisement

Table of Contents
loading