Quectel BG772A-GL Hardware Design page 12

Table of Contents

Advertisement

must not exceed: Operating
Band
LTE BAND 2
LTE BAND 4
LTE BAND 5
LTE BAND 12
LTE BAND 13
LTE BAND 25
LTE BAND 26(814-824)
LTE BAND 26(824-849)
LTE BAND 66
NB-IOT Band 2
NB-IOT Band 4
NB-IOT Band 5
NB-IOT Band 12
NB-IOT Band 13
NB-IOT Band 25
NB-IOT Band 26
NB-IOT Band 66
5. This module must not transmit simultaneously with any other antenna or transmitter
6. The host end product must include a user manual that clearly defines operating requirements and
conditions that must be observed to ensure compliance with current FCC RF exposure guidelines.
For portable devices, in addition to the conditions 3 through 6 described above, a separate approval is
required to satisfy the SAR requirements of FCC Part 2.1093
If the device is used for other equipment that separate approval is required for all other operating
configurations, including portable configurations with respect to 2.1093 and different antenna
configurations.
For this device, OEM integrators must be provided with labeling instructions of finished products.
Please refer to KDB784748 D01 v07, section 8. Page 6/7 last two paragraphs:
A certified modular has the option to use a permanently affixed label, or an electronic label. For a
permanently affixed label, the module must be labeled with an FCC ID - Section 2.926 (see 2.2
Certification (labeling requirements) above). The OEM manual must provide clear instructions explaining
to the OEM the labeling requirements, options and OEM user manual instructions that are required (see
next paragraph).
For a host using a certified modular with a standard fixed label, if (1) the module's FCC ID is not visible
when installed in the host, or (2) if the host is marketed so that end users do not have straightforward
commonly used methods for access to remove the module so that the FCC ID of the module is visible;
then an additional permanent label referring to the enclosed module: "Contains Transmitter Module FCC
ID: XMR2022BG772AGL" or "Contains FCC ID: XMR2022BG772AGL" must be used. The host OEM user
manual must also contain clear instructions on how end users can find and/or access the module and the
FCC ID.
The final host / module combination may also need to be evaluated against the FCC Part 15B criteria for
BG772A-GL_Hardware_Design
7.300
4.300
8.841
8.098
8.514
7.300
8.841
8.841
4.300
7.300
4.300
8.841
8.098
8.514
7.300
8.841
4.300
LPWA Module Series
BG772A-GL Hardware Design
7.30
4.30
5.40
4.91
5.23
7.30
5.36
5.36
4.30
7.30
4.30
5.40
4.91
5.23
4.93
7.30
4.30
11 / 75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpwa module series

Table of Contents