Sign In
Upload
Manuals
Brands
Quectel Manuals
Control Unit
BG600L Series
Quectel BG600L Series Manuals
Manuals and User Guides for Quectel BG600L Series. We have
1
Quectel BG600L Series manual available for free PDF download: Application Note
Quectel BG600L Series Application Note (57 pages)
Brand:
Quectel
| Category:
Control Unit
| Size: 0.83 MB
Table of Contents
About the Document
4
Contents
5
Table of Contents
5
1 Introduction
9
Applicable Modules
9
Usage of TCP/IP at Commands
10
Description of Data Access Modes
12
2 TCP/IP at Commands
14
AT Command Introduction
14
Definitions
14
AT Command Syntax
14
Declaration of at Command Examples
15
Description of TCP/IP at Commands
15
AT+QICSGP Configure Parameters of a TCP/IP Context
15
AT+QIACT Activate a PDP Context
16
AT+QIDEACT Deactivate a PDP Context
17
AT+QIOPEN Open a Socket Service
18
AT+QICLOSE Close a Socket Service
20
AT+QISTATE Query Socket Service Status
21
AT+QISEND Send Data
23
AT+QIRD Retrieve the Received TCP/IP Data
25
AT+QISENDEX Send Hex String Data
26
AT+QISWTMD Switch Data Access Mode
27
AT+QPING Ping a Remote Host
28
AT+QNTP Synchronize Local Time with NTP Server
30
AT+QIDNSCFG Configure Address of DNS Server
31
AT+QIDNSGIP Get IP Address by Domain Name
31
AT+QICFG Configure Optional Parameters
32
AT+QISDE Control Whether to Echo the Data for AT+QISEND
36
AT+QIGETERROR Query the Last Error Code
36
Description of Urcs
37
QIURC: "Closed" Indicate Connection Closed
37
QIURC: "Recv" Indicate Incoming Data
38
QIURC: "Incoming Full" Indicate Incoming Connection Reaches the Limit
38
QIURC: "Incoming" Indicate Incoming Connection
38
QIURC: "Pdpdeact" Indicate PDP Deactivation
39
3 Examples
40
Configure and Activate a Context
40
Configure a Context
40
Activate a Context
40
Deactivate a Context
40
TCP Client Works in Buffer Access Mode under Ipv4
40
Set up a TCP Client Connection and Enter Buffer Access Mode
40
Send Data in Buffer Access Mode
41
Retrieve Data from Remote Server in Buffer Access Mode
41
Close a Connection
42
TCP Client Works in Buffer Access Mode under Ipv6
42
Set up a TCP Client Connection and Enter Buffer Access Mode
42
Send Data in Buffer Access Mode
42
Receive Data from Remote Server in Buffer Access Mode
43
Close a Connection
43
TCP Client Works in Transparent Transmission Mode
44
Set up a TCP Client Connection and Enter Transparent Transmission Mode
44
Send Data in Transparent Transmission Mode
44
Retrieve Data from Remote Server in Transparent Transmission Mode
44
Close a TCP Client
44
TCP Client Works in Direct Push Mode
44
Set up a TCP Client Connection and Enter Direct Push Mode
44
Send Data in Direct Push Mode
45
Retrieve Data from Remote Server in Direct Push Mode
45
Close a TCP Client
45
TCP Server Works in Buffer Access Mode under Ipv4 Network
46
Start a TCP Server
46
Accept TCP Incoming Connection
46
Retrieve Data from Incoming Connection
46
Close a TCP Server
47
TCP Server Works in Buffer Access Mode under Ipv6 Network
47
Start a TCP Server
47
Accept TCP Incoming Connection
47
Retrieve Data from Incoming Connection
47
Switch Incoming Connection to Transparent Transmission Mode
48
Close a TCP Server
48
UDP Service under Ipv4 Network
48
Start a UDP Service
48
Send UDP Data to Remote Client
49
Retrieve Data from Remote Client
49
Close a UDP Service
49
UDP Service under Ipv6 Network
49
Start a UDP Service
49
Send UDP Data to Remote Client
50
Receive Data from Remote Client
50
UDP Client with RAI Feature
50
Start a UDP Client
50
Send UDP Data with RAI Information
51
Close a UDP Client
51
Ping
52
Synchronize Local Time
52
Getting the Last Error Code
53
4 Summary of Result Codes
54
5 Appendix A References
56
Advertisement
Advertisement
Related Products
Quectel BG96
Quectel BG77
Quectel BG96-NA
Quectel BG770A-GL
Quectel BG950A-GL
Quectel BG951A-GL
Quectel BG772A-GL
Quectel BC95
Quectel BC66
Quectel BC950N-N1
Quectel Categories
Control Unit
GSM/GPRS Modules
Motherboard
Wireless modules
GPS
More Quectel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL