Configuration of Instrumentation System
Unit
Name
information
C200H Special
Analog Input Unit
I/O Unit
Analog Output Unit 8 outputs (select from 1 to 5 V, 0 to
Analog Input/Out-
put Unit
Note
Name
Analog Input/Output Unit
Analog Input Unit
Analog Output Unit
Isolated-type Thermocouple
Input Unit
Isolated-type Temperature-
resistance Thermometer Input
Unit
Isolated-type High-resolution
Input Unit with Fully Universal
Inputs
Isolated-type General-pur-
pose Input Unit with Fully Uni-
versal Inputs
Note
48
Specification
8 inputs (select from 1 to 5 V, 4 to 20
mA, 0 to 10 V, or −10 to 10 V), Res-
olution: 1/4000
10 V, or −10 to 10 V), Resolution:
1/4000
8 outputs (4 to 20 mA), Resolution:
1/4000
2 inputs (1 to 5 V, 4 to 20 mA, etc.)
2 outputs (1 to 5 V, 4 to 20 mA, etc.)
In the case of an analog output Field Terminal block, select the function block
according to the Unit model.
CJ Series
Specification
4 inputs (1 to 5 V, 4 to 20 mA, etc.)
2 outputs (1 to 5 V, 0 to 10 mA, etc.)
4 inputs (1 to 5 V, 4 to 20 mA, etc.)
4 inputs (1 to 5 V, 4 to 20 mA, etc.)
4 inputs (high-speed model)
(1 to 5 V, 4 to 20 mA, etc.)
4 outputs (1 to 5 V/4 to 20 mA, etc.)
8 outputs (1 to 5 V, etc.)
8 outputs (4 to 20 mA)
2 outputs (1 to 5 V/4 to 20 mA, etc.)
4 inputs (B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII, mV)
2 inputs (B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII)
4 inputs (Pt100, JPt)
2 inputs (Pt100, JPt100, Pt50, Ni508.4) CJ1W-PTS16
2 inputs (1 to 5 V, 4 to 20 mA)
4 inputs (K, J, T, E, L, U, N, R, S, B,
WRe5-26, PLII, Pt100 (JIS, IEC 3-
wire), JPt100 (3-wire), Pt1000 (3-wire),
Pt100 (3-wire), Pt100 (JIS, IEC 4-wire),
4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to
1.25 V, 0 to 5 V, 0 to 10 V, ±100 mV, -
1.25 to 1.25 V, -5 to 5 V, -10 to 10 V)
4 inputs (K, J, T, L, R, S, B, Pt100,
Pt1000, JPt100, 4 to 20 mA, 0 to
20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V))
In data exchange above, the Loop Controller handles analog I/O signals not in
engineering units but in percentage units. For example, the data 0000 to 0F0A
(FF38 to 1068) Hex from the Analog Input Unit for input 4 to 20 mA (3.2 to
Model
C200H-AD003
C200H-DA003
C200H-DA004
C200H-MAD01
Model
CJ1W-MAD42
AI 4-point/AO 2-point Ter-
minal (Block Model 583)
CJ1W-AD041-V1
AI 4-point Terminal
(Block Model 586)
CJ1W-AD081-V1
AI 8-point Terminal
(Block Model 584)
CJ1W-ADG41
AI 4-point Terminal
(Block Model 581)
CJ1W-DA041
AO 4-point Terminal
(Block Model 587)
CJ1W-DA08V
AO 8-point Terminal
(Block Model 585)
CJ1W-DA08C
AO 8-point Terminal
(Block Model 585)
CJ1W-DA021
AO 2-point Terminal
(Block Model 591)
CJ1W-PTS51
AI 4-point Terminal
(Block Model 566)
CJ1W-PTS15
AI 2-point Terminal
(Block Model 571)
CJ1W-PTS52
AI 4-point Terminal
(Block Model 567)
AI 2-point Terminal
(Block Model 571)
CJ1W-PDC15
AI 2-point Terminal
(Block Model 571)
CJ1W-PH41U
AI 4-point Terminal
(Block Model 572)
CJ1W-AD04U
AI 4-point Terminal
(Block Model 573)
Section 1-2
Function block
AI 8-point Terminal
(Block Model 551)
AO 8-point Terminal
(Block Model 552)
AO 8-point Terminal
(Block Model 552)
AI 2-point/AO 2-point
Terminal (Block
Model 553)
Function block