Functional Element Versions and Programming Devices
Use the above display to confirm the unit version of the CPU Unit connect-
ed online.
The Programming Device that supports the functional element version code
must be used to enable all the functions in the corresponding functional ele-
ment.
Note Upgrading versions is not necessary if only the basic functions of the CPU
Unit element are required.
CPU Unit Element
Loop Controller
Functional
element name
CS1G/H-
CPUH
CS1D-CPUH
CJ1G-CPUH
Functional element version
code for CPU Unit element
Functional
CX-Process Tool
element version
Pre-Ver. 2.0
---
Ver. 2.0
Ver. 3.0
Ver. 4.0
Ver. 1.1
Ver. 3.0
Ver. 4.0
Programming Device
CX-Programmer
(See note.)
---
Ver. 4.0 or higher
Ver. 5.0 or higher
Ver. 7.0 or higher
Ver. 4.0 or higher
Ver. 5.0 or higher
Ver. 7.0 or higher