Response
SREF CK1
0-159
LD 74 Define data blocks for DASS2 protocols.
Prompt
Response
REQ
NEW CHG OUT
PRT END
TYPE
DDSL
S2
(0)1
DDSL
Group G
0-15
16-159
Group H
0-63
16-159
Copyright © 2007, Nortel Networks
.
Description
The secondary reference loop numbers for clock controller 1.
Notes:
LD 73 must be run to set values.
To remove a reference loop and return to free run, enter X.
To leave a reference loop unchanged, enter <cr>.
To enable synchronization, set the tracking LD 60. To track on a
primary or secondary reference clock, the command is:
TRCK
PCK
(for Primary)
SCK
(for Secondary)
FRUN (for Free-Run)
The Clock Controller will be in free-run mode when enabled.
It should stay in this mode for several minutes before being
switched to tracking mode.
Description
Create new data base, modify existing data base, remove data
block, print data block, terminate program activity
Digital Signaling Link
DCHI switch setting
If the NT5K35 is used, then set S2 to 0;
If the NT5K75 or NT6D11AE is used:
set S2 to 0 for standard mode addressing;
set S2 to 1 for expanded mode addressing.
The D-channel port number, entered in LD 17.
If 0 entered to S2 prompt;
If 1 entered to S2 prompt.
If 0 entered to S2 prompt;
If 1 entered to S2 prompt.