Nortel Communication Server 1000 Manual page 136

Hide thumbs Also See for Communication Server 1000:
Table of Contents

Advertisement

136 DCHI installation and removal
Installing the NTAG54 Daughterboard
Set the address for the NTAG54 (see the Switch settings section to set the
address). If a NTAG54 is present on a Dual PRI card then an external D
Channel should not be connected to P3. If a NTAG54 is present the LED
DCH lights up.
Procedure 1
Installing the NTAG54 card
Step
1
2
Removing the NTAG54 Daughterboard
Removing the NTAG54 card
Copyright © 2007, Nortel Networks
.
Features (NN43001-569) or ISDN Basic Rate Interface: Features
(NN43001-580) document for these test procedures.
Either the NTAG54 or the DPRI card may be installed first. However,
DPRI loops must be configured in software before defining DCH links.
CAUTION
CAUTION WITH ESDS DEVICES
The static discharge bracelet located inside the cabinet must be
worn before handling circuit cards. Failure to wear the bracelet
can result in damage to the circuit cards.
Action
Unpack and inspect the NTAG54 Daughterboard.
Mount the NTAG54. The NTAG54 can be mounted on any DDP2
NT5D97AD. Slots that are occupied by BTU's prevent the insertion
of daughterboards.
The NTAG54 comes with 4 stand-offs so that it can be mounted
onto the Dual PRI. These are easily pushed into 4 corresponding
mounting holes on the Dual PRI.
The NTAG54 is mounted so that it mates correctly with P9 and
P11 on the Dual PRI motherboard.
CAUTION
CAUTION WITH ESDS DEVICES
The static discharge bracelet located inside the cabinet must be
worn before handling circuit cards. Failure to wear the bracelet
can result in damage to the circuit cards.
Nortel Communication Server 1000
DASS2 Fundamentals
NN43001-571 02.01 Standard
Release 5.5 7 December 2007
—End—