eka EKF 611 CTC Original Operating And Instruction Manual page 19

Table of Contents

Advertisement

Electronic convection oven rev. .4___________________________________MODD. EKF 611 CTC – EKF 1011 CTC
3. DELTA T VALUE
Use the keys
and
confirm the choice with the
With "BAKING IN PROGRESS": the display shows the set temperature in the direction of
the actual temperature detected by the core probe in the direction of the symbol
The display shows the set temperature in the direction of the symbol
temperature detected in the cooking chamber in the direction of the symbol
When the OVERVIEW SCREEN shows the CORE TEMPERATURE parameter
parameter
, to go back to setting the TIME parameter
Use the "STEP"
-
-
Use the "SELECT" key
-
Use the "STEP"
-
Use the "SELECT"
At the end of these operations the display will show the red OVERVIEW SCREEN (if the
PREHEATING function is not set) to indicate the TIME parameter is missing ("00.00").
4.3.3.3 HUMIDITY/STEAM setting(Parameter screen)
Use the keys
e
100%). After that confirm the choice with the "SELECT"
4.3.3.4 "PREHEATING" setting (Overview screen)
Use the
key and the display shows the relevant PARAMETER SCREEN.
Use the
key ("ON") to activate the function or the
cases use the "SELECT"
after 5".
During the preheating stage, the display reads "PREHEATING IN PROGRESS" and no value is
shown in the direction of the TIME parameter
This means that the preheating time is not included in the cooking time.
When the preheating temperature is reached (temperature set in cooking chamber increased by
40°C: this temperature is maintained if the door is not opened), and intermittent buzzer goes off
and the words "PREHEATING OK OPEN THE DOOR" flashes on the display. Open the door, put
the food in the oven, close the door again: the cooking cycle starts automatically.
4.3.3.5 AIR FLOW SPEED setting (Overview screen)
The possibility to set 3 speed levels of air flows inside the cooking chamber makes it possible to
bake any type of food, from the most delicate and lightest to that needing higher heat
conveyance.
_________________________________________________________________________________________ page 19
to increase or decrease the temperature (from 0°C to 100°C). After that
key.
"SELECT"
key to select the DELTA T parameter
(the display shows the PARAMETER SCREEN);
key to select the TEMPERATURE IN COOKING CHAMBER parameter
key.
to increase or decrease the humidity/steam value
key to confirm the choice, otherwise it is confirmed automatically
:
;
key.
key ("OFF") to deactivate it. In both
(---).
and
.
and the actual
.
and the DELTA T
;
(from 10% to

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekf 611 ctc/0/037Ekf 611 ctc/0/048Ekf 1011 ctc

Table of Contents