Pro Tip: when turing on the spool gun also
turn on remote as the HTP spoolgun has
remote control functions build in.
MIG MANUAL POLARITY
With this function it is possible change the
polarity of the welding gun only in Manual
Mode. This function is used when it is
necessary to weld a gasless flux cored wire.
Press the button
menu.
to go into the settings
With the button
Press the button CHANGE ( Fig.4,ref.11 )
and next to MIG-Manual pol . it is possible
see STD ( standard ) or REV ( reverse ).
If reverse polarity is chosen on the display
this is what it is possible see .
The REVers polarity is used when you want
to use a flux-cored wire without gas

FACTORY RESET

If it is necessary to do a factory reset press the
button
to go into the settings menu.
With the button
Press the button CHANGE ( Fig.4,ref.11 )
and then press the button Ѵ
After that the machine will be on TIG DC
mode with HF ON at 60
select MIG-Manual pol .
select Factory Reset .